Auxiliary Engines - N-1 Redundancy Check
Verify electrical load coverage with the largest auxiliary generator out per SOLAS Chapter II-1 redundancy rule.
Formula, assumptions, limits
SOLAS Chapter II-1 Part D requires the main electrical source to cover essential services with the largest single generator out (the N-1 rule). The remaining generators must provide enough capacity for essential services plus the largest single motor starting transient (e.g. bow thruster start). Margin of 10 to 20 percent above N-1 minimum is typical industry practice.
Symbol legend
SymbolMeaningUnitSource
Number of generators onlineunitsoperations Capacity per generatorkWnameplate Essential ship services loadkWload schedule Largest single transient loadkWload schedule
In short
Verify electrical load coverage with largest generator out per SOLAS II-1.