Marine Boiler - Operational Pressure Check
Verify boiler operating pressure against design pressure, safety valve set point and classification limits.
- Operating margin
- bar
- Margin %
- %
- Compliance
Formula, assumptions, limits
Operating pressure must remain below design pressure with reasonable margin. Safety valve set typically at design pressure (some class rules allow up to 1.05 x design). Hydrostatic test at 1.5 x design at construction. Operating beyond design pressure is forbidden under classification society rules and indicates need for immediate shutdown and investigation. Margin below 5 percent of design typically indicates unusual operating condition; margin below 0 indicates over-pressure event.
Symbol legend
SymbolMeaningUnitSource
Boiler design pressurebar(g)nameplate Current operating pressurebar(g)gauge Safety valve set pressurebar(g)SV stamp
In short
Verify boiler operating pressure against design pressure and safety valve setting.