ShipCalculators.com

IEC 61363 - Ship Short-Circuit Current

Initial symmetrical short-circuit current (I_k) at a ship's main switchboard per IEC 61363-1 - used to verify switchgear breaking capacity.

Short circuitIEC 61363Fault
Gen rated current
3,936A
Initial I_k
52.5kA

Formula, assumptions, and limits

Ik′′=InXd′′⋅ngenI_k'' = \frac{I_n}{X_d''} \cdot n_{gen}
SymbolMeaningUnit
InI_nGenerator rated currentA
Xd′′X_d''Subtransient reactancepu
ngenn_{gen}Generators in parallel

Source: IEC 61363-1

In short

Initial symmetrical short-circuit current (I_k) at a ship's main switchboard per IEC 61363-1 - used to verify switchgear breaking capacity.

Learn the theory Marine Electrical Generation and Distribution