Safety-floor check per MEPC.1/Circ.850/Rev.3. Ensures a ship has enough installed propulsion to manoeuvre safely in adverse weather, even after EEXI power limitations.

IMODesignMEPC.1/Circ.850
Loading calculator…

Formula, assumptions, and limits

Pmin={0.0687DWT+2924.4&DWT<145,000 0.0689DWT+2937.0&DWT145,000P_\text{min} = \begin{cases} 0.0687 \cdot \text{DWT} + 2924.4 \& \text{DWT} < 145{,}000 \ 0.0689 \cdot \text{DWT} + 2937.0 \& \text{DWT} \ge 145{,}000 \end{cases}
SymbolMeaningUnit
PminP_\text{min}Minimum installed MCR requiredkW
DWTDWTDeadweight tonnaget

Source: IMO MEPC.1/Circ.850/Rev.3

In short

Safety-floor check for minimum installed propulsion power per IMO MEPC.1/Circ.850/Rev.3 Level 1.

Learn the theory BIMCO CII and Emissions Clauses