ShipCalculators.com

Sewage Holding Tank - Capacity Check

Required sewage holding-tank capacity for a given POB and passage length per MARPOL Annex IV special-area carriage rules - baseline 70 L/person·day.

SewageMARPOL IVCapacity
Loading calculator…

Formula, assumptions, and limits

Vholding=POBdqpc(1+m)V_{holding} = \text{POB} \cdot d \cdot q_{pc} \cdot (1 + m)
SymbolMeaningUnit
POBPOBPersons on board (crew + pax)pax
ddRetention days requiredday
qpcq_{pc}Per-capita generation rateL/day
mmSafety margin

Source: MARPOL Annex IV; MEPC.159(55) STP Guidelines

In short

Required sewage holding-tank capacity for a given POB and passage length per MARPOL Annex IV special-area carriage rules - baseline 70 L/person\u00b7day.

Learn the theory Marine Sewage and Grey Water Treatment Systems