ShipCalculators.com

LPG / Gas Carrier CII

CII for LPG/ethylene/ammonia gas carriers. MEPC.353(78) uses two reference lines depending on size: ≥ 65,000 DWT uses (14405E7, 2.071); < 65,000 DWT uses (8104, 0.639).

Ship typeGas carrier

Ship & voyage

Fuel

VLGCs often burn boil-off LPG directly in dual-fuel engines; others burn VLSFO/MGO.

Reference line used
Gas carrier ≥ 65,000 DWT
Attained CII
6.329g CO₂ / (dwt·nm)
Required CII
8.731g CO₂ / (dwt·nm)
Rating
A
Major superior performance. No corrective action required.

Formula, assumptions, and limits

CIIrequired=asize⋅DWT−csize⋅(1−Z)\text{CII}_\text{required} = a_\text{size} \cdot \text{DWT}^{-c_\text{size}} \cdot (1 - Z)
SymbolMeaningUnit
SizebandSize bandaacc
≥65,000DWT≥ 65,000 DWT14405E72.071
<65,000DWT< 65,000 DWT8,1040.639

Source: IMO MEPC.353(78), MEPC.338(76) as amended by MEPC.400(83), and MEPC.354(78); SIGTTO - Gas carrier operational guidance

In short

CII for LPG, ethylene and ammonia gas carriers using the size-split MEPC.353(78) reference lines (≥ 65 kt and < 65 kt DWT).

Learn the theory Gas Carrier Types: LPG and LNG Ship Classes