ShipCalculators.com

WHR Exhaust Economizer - Steam Generation

Exhaust-gas economizer steam production rate given exhaust mass flow, inlet T, and evaporator pinch-point temperature.

WHREconomizerSteam
Heat available
4,125kW
Steam production
7,262kg/h

Formula, assumptions, and limits

m˙steam=m˙exh⋅cp⋅ΔThfg\dot m_{steam} = \frac{\dot m_{exh} \cdot c_p \cdot \Delta T}{h_{fg}}
SymbolMeaningUnit
m˙exh\dot m_{exh}Exhaust mass flowkg/s
cpc_pSpecific heat of exhaustkJ/kg·K
hfgh_{fg}Latent heat of steamkJ/kg

Source: MAN ES WHRS Guidelines

In short

Exhaust-gas economizer steam production rate given exhaust mass flow, inlet T, and evaporator pinch-point temperature.

Learn the theory Marine Auxiliary Engines and Generators