ShipCalculators.com

How much bigger is an ammonia, methanol or LNG tank than a VLSFO tank?

Same energy as a VLSFO, HFO or MGO tank or voyage · ammonia, methanol, ethanol, LNG, propane, butane, liquid hydrogen, HVO, FAME · IMO (MEPC.364(79), MEPC.391(81)) or FuelEU Annex II heating values · IGF Code 6.8 filling limits · your space factor and pilot share · Updated 2 November 2026

Published by ShipCalculators.com. Method checked against IMO MEPC.364(79) and MEPC.391(81), Regulation (EU) 2023/1805 Annex II and IGF Code 6.8 and MSC.1/Circ.1621, 1666, 1687, 1701 on 31 October 2026. How calculators are checked

Answer

For the energy in a 2,000 m³ VLSFO tank filled to 98%, 78,083 GJ at the IMO heating values of MEPC.364(79) and MEPC.391(81), refrigerated ammonia needs 4,198 t, or 6,159 m³ of liquid at −33 °C: 3.14 times the VLSFO volume and 2.16 times its mass. Methanol needs 2.53 times the volume, LNG 1.84.

Change the inputs below to recompute.

On this page

Fuel-only and tank volume ratios

The fuel-only volume ratio is the liquid volume of a fuel that carries the same energy as a unit volume of the reference fuel: the reference fuel’s lower calorific value times its density, divided by the same product for the new fuel. IMO resolutions MEPC.364(79) and MEPC.391(81) and FuelEU Maritime Annex II print the heating values.1,2,3 The tank ratio adds each tank’s filling limit, which the IGF Code sets at 98% for liquefied gas fuels,5 and the hull space ratio adds the space an arrangement takes around the tank, for which no IMO or EU text gives a figure.

Tank volume for the same energy

Filled in with a typical ship. Change only what differs on yours; the answer is at the foot of the card.

The fuel your ship burns today

Fuel today
What do you know about it?

Tank volume

2,000 m³

Daily use, for how long it lasts

30 t/day

The fuel that would replace it

  • Ammonia, refrigerated holds 18.6 MJ/kg, against 40.2 MJ/kg for VLSFO. It weighs and its tank is filled to . Density at −33.3 °C and 1.013 bar, NIST. Filling limit: IGF Code 6.8.1. Tap a highlighted figure to change it.

Your ship's own figuresoptional

  • Today's fuel weighs and fills of its tank.Bunker delivery note at 15 °C; tank capacity plan.
  • The new tank takes its volume in hull space.1 means no allowance for insulation, cofferdams or tank shape.
  • The engine takes of its energy from pilot MGO and runs at of its efficiency on today's fuel.Engine maker's data sheet.
  • For a gas fuel, the loading limit from the relief valve setting: relative density at the reference temperature and at loading give the loading limit once both are entered. IGF Code 6.8.1: LL = 98% × ρR ÷ ρL, never above 95% where 6.8.3 applies.
Heating values
Units

A 2,000 m³ VLSFO tank, 98% full, holds the energy of 6,159 m³ of ammonia, refrigerated: 3.14× the volume and 2.16× the mass. Its tank, 98% full: 6,285 m³.

The energy of a 2,000 m³ VLSFO tank 98% full, 78,083 GJ, takes 4,198 t of ammonia, refrigerated: 6,159 m³ of liquid, 3.14× the VLSFO volume. At 98% full its tank is 6,285 m³; the same 2,000 m³ tank would last 20.6 days against 64.7 days.

Your result

Ammonia −33 °C for the same energy

Liquid volume
6,159 m³
Volume ratio
3.14×of the VLSFO volume
Mass ratio
2.16×
Mass
4,198 t

Fuel only and with the tank

Fuel only3.14×heating value and density
With the tank3.14×98% full, × 1.00

The energy of a 2,000 m³ VLSFO tank 98% full, 78,083 GJ, takes 4,198 t of ammonia, refrigerated: 6,159 m³ of liquid, 3.14× the VLSFO volume. At 98% full its tank is 6,285 m³; the same 2,000 m³ tank would last 20.6 days against 64.7 days.

The tanks on one scale

Liquid volume, every fuel

VLSFO = 1VLSFO = 1MGOMGO: 1.04×1.04×LNGLNG: 1.84×1.84×PropanePropane: 1.48×1.48×ButaneButane: 1.45×1.45×MethanolMethanol: 2.53×2.53×EthanolEthanol: 1.88×1.88×Ammonia −33 °CAmmonia, refrigerated: 3.14×3.14×Ammonia 25 °CAmmonia, pressurized: 3.55×3.55×Liquid H₂Liquid hydrogen: 4.69×4.69×HVOHVO: 1.17×1.17×FAMEFAME: 1.22×1.22×

IMO and FuelEU heating values

IMO values3.14×6,159 m³
FuelEU values3.17×6,205 m³

Bunker equivalents

1 t of VLSFO
2.16 t · 3.17 m³
1 m³ of VLSFO
2.14 t · 3.14 m³

Tank and endurance

Tank at 98% full
6,285 m³
Hull space
6,285 m³
Pilot MGO
none
Energy
78,083 GJ
Same tank lasts
20.6 days
VLSFO lasts
64.7 days

Volumes at the density shown; a VLSFO lighter than 991 kg/m³ lowers every volume ratio in proportion.

What this volume means for the ship

Ammonia, refrigerated carries 18.6 MJ/kg against 40.2 for VLSFO, so the same energy takes 2.16× the mass. At 682 kg/m³ against 991, that mass fills 3.14× the volume. This is the fuel-only ratio that the IMO heating values and the density fix.

The tank figures depend on the design. A 98% filling limit (IGF Code 6.8.1) makes the tank 6,285 m³; no space factor is applied: no IMO, EU or IACS text gives one for any tank type, so the hull space equals the tank volume until you enter your design's figure. Against the 2,000 m³ VLSFO tank that is 3.14×.

Filled with ammonia, refrigerated, the same 2,000 m³ tank holds 0.32× the energy, 20.6 days at the 30 t a day of VLSFO used here, against 64.7 days. The FuelEU Maritime values differ for some fuels (LNG 49.1 against 48.0 MJ/kg); switch the heating values to see them.

Cite or share this calculation

ShipCalculators.com, “Alternative Fuel Tank Volume Calculator: Ammonia, Methanol, LNG and Hydrogen vs VLSFO.” Method: equal delivered energy; mass = energy ÷ lower calorific value; volume = mass ÷ density; tank = volume ÷ filling limit; heating values from IMO MEPC.364(79) and MEPC.391(81). Inputs: Comparing ammonia, refrigerated (682 kg/m³, 98% full) with the energy in a 2,000 m³ VLSFO tank 98% full (991 kg/m³), 78,083 GJ on the IMO heating values: 6,159 m³ of liquid, 3.14× the volume. Result: 6,159 m³ of ammonia, refrigerated, 3.14× the volume, 4,198 t, tank 6,285 m³. https://shipcalculators.com/calculators/alternative-fuel-tank-volume

The citation names ShipCalculators.com as publisher; copying it adds today's date.

Drawings of the tanks and every fuel

The tanks on one scale

VLSFO tank, 98% fullVLSFO tank, 98% full: 2,000 m³Liquid: 1,960 m³2,000 m³ · 1.00×Ammonia, refrigerated tank, 98% fullAmmonia, refrigerated tank, 98% full: 6,285 m³Liquid: 6,159 m³6,285 m³ · 3.14×Hull space, no allowanceHull space, no allowance: 6,285 m³6,285 m³ · 3.14×No pilot fuel0 m³
VLSFO tank, 98% fullVLSFO tank, 98% full: 2,000 m³Liquid: 1,960 m³2,000 m³ · 1.00×Ammonia −33 °C tank, 98% fullAmmonia −33 °C tank, 98% full: 6,285 m³Liquid: 6,159 m³6,285 m³ · 3.14×Hull space, no allowanceHull space, no allowance: 6,285 m³6,285 m³ · 3.14×No pilot fuel0 m³

Solid fill: the liquid. Outline: the tank at its filling limit. Dashed: the hull space at the space factor.

Liquid volume for the same energy, every fuel

VLSFO = 1VLSFO = 1MGOMGO: 1.04×1.04×LNGLNG: 1.84×1.84×PropanePropane: 1.48×1.48×ButaneButane: 1.45×1.45×MethanolMethanol: 2.53×2.53×EthanolEthanol: 1.88×1.88×Ammonia −33 °CAmmonia, refrigerated: 3.14×3.14×Ammonia 25 °CAmmonia, pressurized: 3.55×3.55×Liquid H₂Liquid hydrogen: 4.69×4.69×HVOHVO: 1.17×1.17×FAMEFAME: 1.22×1.22×
VLSFO = 1VLSFO = 1MGOMGO: 1.04×1.04×LNGLNG: 1.84×1.84×PropanePropane: 1.48×1.48×ButaneButane: 1.45×1.45×MethanolMethanol: 2.53×2.53×EthanolEthanol: 1.88×1.88×Ammonia −33 °CAmmonia, refrigerated: 3.14×3.14×Ammonia 25 °CAmmonia, pressurized: 3.55×3.55×Liquid H₂Liquid hydrogen: 4.69×4.69×HVOHVO: 1.17×1.17×FAMEFAME: 1.22×1.22×

Times the VLSFO volume, each fuel at its own density; the fuel compared in navy, less its pilot share.

Mass for the same energy, every fuel

VLSFO = 1VLSFO = 1MGOMGO: 0.94×0.94×LNGLNG: 0.84×0.84×PropanePropane: 0.87×0.87×ButaneButane: 0.88×0.88×MethanolMethanol: 2.02×2.02×EthanolEthanol: 1.50×1.50×Ammonia −33 °CAmmonia, refrigerated: 2.16×2.16×Ammonia 25 °CAmmonia, pressurized: 2.16×2.16×Liquid H₂Liquid hydrogen: 0.34×0.34×HVOHVO: 0.91×0.91×FAMEFAME: 1.08×1.08×
VLSFO = 1VLSFO = 1MGOMGO: 0.94×0.94×LNGLNG: 0.84×0.84×PropanePropane: 0.87×0.87×ButaneButane: 0.88×0.88×MethanolMethanol: 2.02×2.02×EthanolEthanol: 1.50×1.50×Ammonia −33 °CAmmonia, refrigerated: 2.16×2.16×Ammonia 25 °CAmmonia, pressurized: 2.16×2.16×Liquid H₂Liquid hydrogen: 0.34×0.34×HVOHVO: 0.91×0.91×FAMEFAME: 1.08×1.08×

Times the VLSFO mass: the ratio of the heating values.

Days the same tank lasts, every fuel

VLSFO 64.7 dVLSFO 64.7 dMGOMGO: 62.5 d62.5 dLNGLNG: 34.0 d34.0 dPropanePropane: 43.7 d43.7 dButaneButane: 44.7 d44.7 dMethanolMethanol: 25.6 d25.6 dEthanolEthanol: 34.4 d34.4 dAmmonia −33 °CAmmonia, refrigerated: 20.6 d20.6 dAmmonia 25 °CAmmonia, pressurized: 18.2 d18.2 dLiquid H₂Liquid hydrogen: 13.8 d13.8 dHVOHVO: 55.3 d55.3 dFAMEFAME: 53.3 d53.3 d
VLSFO 64.7 dVLSFO 64.7 dMGOMGO: 62.5 d62.5 dLNGLNG: 34.0 d34.0 dPropanePropane: 43.7 d43.7 dButaneButane: 44.7 d44.7 dMethanolMethanol: 25.6 d25.6 dEthanolEthanol: 34.4 d34.4 dAmmonia −33 °CAmmonia, refrigerated: 20.6 d20.6 dAmmonia 25 °CAmmonia, pressurized: 18.2 d18.2 dLiquid H₂Liquid hydrogen: 13.8 d13.8 dHVOHVO: 55.3 d55.3 dFAMEFAME: 53.3 d53.3 d

Each fuel at its own filling limit; amber dashes: the VLSFO tank.

The same figures in a table

Every fuel for the same energy
Fuelm³× vol.× mass
MGO2,0321.040.94
LNG3,6151.840.84
Propane2,9031.480.87
Butane2,8421.450.88
Methanol4,9612.532.02
Ethanol3,6911.881.50
Ammonia −33 °C6,1593.142.16
Ammonia 25 °C6,9623.552.16
Liquid H₂9,1914.690.34
HVO2,2961.170.91
FAME2,3831.221.08

The energy of a 2,000 m³ VLSFO tank 98% full, 78,083 GJ, takes 4,198 t of ammonia, refrigerated: 6,159 m³ of liquid, 3.14× the VLSFO volume. At 98% full its tank is 6,285 m³; the same 2,000 m³ tank would last 20.6 days against 64.7 days.

The comparison in plain words

Take the energy you carry now: the tank volume times how full it is, times the density, times the heating value. Divide that energy by the new fuel’s heating value to get the tonnes, and by its density to get the cubic meters of liquid. Divide by the new tank’s filling limit for the tank size, and multiply by a space factor if your design has one. For ammonia against VLSFO that is 40.2 ÷ 18.6 = 2.16 times the mass, and 2.16 × 991 ÷ 681.6 = 3.14 times the volume.

Formula, assumptions, and limits

The calculator holds the ship’s energy fixed, divides it by the new fuel’s heating value to get the mass, divides the mass by the density to get the liquid volume, and divides that by the filling limit to get the tank.

Formula

The energy in the reference tank, then the mass, liquid volume, tank and hull space of fuel ii:

E=Vt,ref Kref ρref LCVrefE = V_{t,\text{ref}} \, K_{\text{ref}} \, \rho_{\text{ref}} \, \text{LCV}_{\text{ref}}mi=E (1−p)η LCVim_i = \frac{E \, (1 - p)}{\eta \, \text{LCV}_i}Vf,i=miρiV_{f,i} = \frac{m_i}{\rho_i}Vt,i=Vf,iKi,Vs,i=Si Vt,iV_{t,i} = \frac{V_{f,i}}{K_i}, \qquad V_{s,i} = S_i \, V_{t,i}

The fuel-only volume ratio, with no pilot and the same engine efficiency:

Vf,iVf,ref=LCVref ρrefLCVi ρi\frac{V_{f,i}}{V_{f,\text{ref}}} = \frac{\text{LCV}_{\text{ref}} \, \rho_{\text{ref}}}{\text{LCV}_i \, \rho_i}
  • EE: energy delivered, GJ. From a voyage it is the daily consumption in tonnes times the days times LCVref\text{LCV}_{\text{ref}}; from the tonnes bunkered, the tonnes times LCVref\text{LCV}_{\text{ref}}.
  • LCV\text{LCV}: lower calorific value, MJ/kg, which is the same number as GJ/t.
  • ρ\rho: liquid density, kg/m³, at the storage temperature shown beside it.
  • KK: filling limit, the share of the tank the liquid may occupy.
  • SS: space factor, hull space per m³ of tank, 1 for no allowance.
  • pp: pilot fuel share of the energy, burned as MGO at 42.7 MJ/kg.
  • η\eta: the engine’s efficiency on fuel ii as a fraction of its efficiency on the reference fuel, 1 when they are the same.

Derivation

Lower calorific value is “the amount of heat that would be released by the complete combustion of a specified fuel”, in the words of MEPC.391(81).2 Mass for a given energy is therefore energy over LCV, and the mass ratio of two fuels is the inverse ratio of their LCVs: 40.2 ÷ 18.6 = 2.161 for ammonia against VLSFO. Volume is mass over density, which brings in the second ratio: 991 ÷ 681.6 = 1.454. Their product, 3.142, is the fuel-only volume ratio.

The tank follows from the IGF Code’s definition of the filling limit, “the maximum liquid volume in a fuel tank relative to the total tank volume” (paragraph 2.2.16).5 The pilot fuel, where an engine needs one, comes out of the same energy and goes to its own MGO tank at 98%.

Assumptions

  • Equal delivered energy. The ship needs the same energy at the propeller and the generators whatever the fuel, unless you enter a different engine efficiency.
  • Heating values from the IMO set by default: MEPC.364(79) for fuel oils, LNG, LPG, methanol and ethanol, MEPC.391(81) for ammonia, hydrogen, HVO and FAME.1,2 VLSFO takes the heavy fuel oil row, 40.2 MJ/kg, which MEPC.391(81) names HFO(VLSFO).
  • Densities at the conditions printed in the reference table below, not at a common temperature.
  • The reference tank and the new tank hold the same energy; endurance uses the daily consumption of the reference fuel.
  • No boil-off, no unpumpable residue, no sludge or settling tank volume.

Worked example

A 2,000 m³ VLSFO tank filled to 98% at 991 kg/m³ holds 1,960 m³, or 1,942.36 t. At 40.2 MJ/kg that is 78,082.9 GJ.

Refrigerated ammonia at 18.6 MJ/kg needs 78,082.9 ÷ 18.6 = 4,198.0 t. At 681.6 kg/m³ that is 4,198.0 ÷ 0.6816 = 6,159.0 m³ of liquid, 3.142 times the VLSFO volume and 2.161 times its mass. At the 98% filling limit of IGF Code 6.8.1 the tank is 6,159.0 ÷ 0.98 = 6,284.7 m³.

At 30 t a day of VLSFO, 1,206.0 GJ a day, the VLSFO tank lasts 64.7 days. Filled with ammonia, the same 2,000 m³ tank holds 2,000 × 0.98 × 0.6816 × 18.6 = 24,848 GJ and lasts 20.6 days.

With methanol at 19.9 MJ/kg and 791.0 kg/m³ and 5% of the energy from pilot MGO, the main fuel is 78,082.9 × 0.95 ÷ 19.9 = 3,727.6 t and 4,712.5 m³, and the pilot is 91.4 t of MGO in a 103.7 m³ tank.

Edge cases and limits

  • Pressurized ammonia. At 25 °C and 10.0 bar the density is 603.0 kg/m³ and the volume ratio 3.55. MSC.1/Circ.1687 says ammonia fuel “should be stored in a refrigerated state at atmospheric pressure”, so this case sits outside the circular’s base design.7
  • Liquid hydrogen. MSC.1/Circ.1701 covers liquefied hydrogen in vacuum-insulated type C independent tanks only, and applies IGF Code 6.8 to them.8
  • The loading limit. For a liquefied gas the 98% holds at the reference temperature, which is set by the relief valve pressure. At a colder loading temperature the limit is LL = 98% × ρR ÷ ρL, lower than 98%; the calculator works it out from two relative densities you enter.5
  • The 95% cap. IGF Code 6.8.2 allows a higher loading limit for well-insulated tanks “but never above 95%”, and MSC.458(101) repeats that cap in a new 6.8.3 for ships constructed on or after 1 January 2024.6
  • Space factor. No IMO, EU or IACS text gives a figure for any tank type, so the calculator applies none until you enter one.

Regulatory basis

The heating values are MEPC.364(79), as amended by MEPC.410(84) without change to the table, and MEPC.391(81) Appendix 2, which MEPC 84 left unamended; MEPC.1/Circ.926 adds an ethanol value of 0.0268 MJ/g.1,2,14 The FuelEU set is Regulation (EU) 2023/1805 Annex II, with liquid biofuels sent to RED Annex III.3,13 The filling limits are IGF Code 6.8 and the circulars for ammonia, hydrogen, methyl and ethyl alcohol and LPG;5,7,8,9,10 the LNG filling rate of 0.95 and the 991, 900 and 450 kg/m³ densities are MEPC.411(84) paragraph 4.2.3.2.4

Common errors

  1. Mixing fuel-only and tank-inclusive ratios. EMSA’s 2022 ammonia study gives LNG 1.8 and ammonia 3.0 against MGO, “not including insulation and secondary barriers”; other sources quote ratios with the tank system in.19
  2. Changing the reference fuel mid-sentence. A ratio against MGO (EMSA) is not a ratio against HFO (ClassNK’s 3.07 for ammonia) or VLSFO.19,20
  3. Using FuelEU’s 41,000 MJ per tonne of VLSFO as a heating value. Annex IV uses it to convert the penalty; the Annex II value is 40.5 MJ/kg.3
  4. Taking ammonia’s density at the wrong state: 681.6 kg/m³ refrigerated against 603.0 pressurized at 25 °C is a 13% difference in volume.11
  5. Reading a pilot share given by mass as a share of energy. MAN Energy Solutions’ paper on the LGIM methanol engine gives “up to 5% of the MCR fuel consumption in diesel oil mode”, a mass figure; convert a mass share with the two heating values before you enter it.21

Heating values and densities of marine fuels

FuelIMO LCV, MJ/kgFuelEU LCV, MJ/kgDensity, kg/m³Condition and source
VLSFO, HFO40.240.5991MEPC.411(84), no temperature
MGO, MDO42.742.7900MEPC.411(84), no temperature
LNG48.049.1450MEPC.411(84); 420 to 470 by composition
Methanol19.919.9791.020 °C, NIST
Ethanol26.827789.320 °C, CRC Handbook via PubChem
Ammonia, refrigerated18.618.6681.6−33.3 °C, 1.013 bar, NIST
Ammonia, pressurized18.618.6603.025 °C, 10.0 bar, NIST
Liquid hydrogen12012070.8−252.9 °C, NIST
Propane46.346.0580.9−42.1 °C, NIST
Butane45.746.0601.3−0.5 °C, NIST
HVO44.044773implied by RED Annex III, ±2%
FAME37.237881implied by NREL 2023, 33.3 MJ/l ÷ 37.8 MJ/kg

The IMO column takes ammonia, hydrogen, HVO and FAME from MEPC.391(81) and the rest from MEPC.364(79); the FuelEU column takes ethanol, HVO and FAME from RED Annex III, as Annex II directs.1,2,3,13 NIST densities are saturated liquid at the stated condition.11,12,15 The 991 kg/m³ for VLSFO is the MEPC.411(84) heavy fuel oil density; a delivered VLSFO is often lighter, and every volume ratio falls in proportion to the density you enter.4

VLSFO = 1VLSFO = 1MGOMGO: 1.04×1.04×LNGLNG: 1.84×1.84×PropanePropane: 1.48×1.48×ButaneButane: 1.45×1.45×MethanolMethanol: 2.53×2.53×EthanolEthanol: 1.88×1.88×Ammonia −33 °CAmmonia, refrigerated: 3.14×3.14×Ammonia 25 °CAmmonia, pressurized: 3.55×3.55×Liquid H₂Liquid hydrogen: 4.69×4.69×HVOHVO: 1.17×1.17×FAMEFAME: 1.22×1.22×
Liquid volume of each fuel for the energy in a 2,000 m³ VLSFO tank at 98% full, as a multiple of the VLSFO volume, on the IMO heating values. Liquid hydrogen needs 4.69 times, pressurized ammonia 3.55, refrigerated ammonia 3.14, methanol 2.53, ethanol 1.88, LNG 1.84, propane 1.48, butane 1.45, FAME 1.22, HVO 1.17 and MGO 1.04.

Filling limits by fuel and where they come from

Only the liquefied gases have a filling limit in an IMO text. IGF Code 6.8.1 caps a liquefied gas fuel tank at 98% at the reference temperature, and the circulars carry that rule to ammonia (MSC.1/Circ.1687, 6.8.1), liquid hydrogen (MSC.1/Circ.1701, 6.8.1) and LPG (MSC.1/Circ.1666, which applies IGF Code chapter 6 without excluding 6.8).5,7,8,10

Methanol and ethanol have none. MSC.1/Circ.1621 asks for cofferdams around integral tanks and 600 mm between the tanks and category A machinery spaces, which costs hull space but sets no fill figure.9 For fuel oil, HVO, FAME and the alcohols, the calculator uses 98% as a convention, the figure MEPC.411(84) gives oil tanks for the EEDI, and says so beside the result.4

Published tank ratios and why they disagree

Three bases appear in print. EMSA’s 2022 study and ClassNK’s Alternative Fuels Insight give fuel-only ratios, against MGO and against HFO (“in liquid form”: LNG 1.89, ammonia 3.07).19,20 The Mærsk Mc-Kinney Møller Center’s 2024 ammonia design study gives tank capacities: 6,000 m³ of ammonia for the range of 2,000 m³ of fuel oil on a Capesize design.22 A 2019 DNV study for SEA\LNG gives figures “including storage systems”, LNG at about 13 MJ/l against 21 MJ/l for the fuel alone.23 Against LNG, refrigerated ammonia takes 1.70 times the liquid volume on this page’s figures (3.14 ÷ 1.84).

The calculator keeps the bases apart. The fuel-only ratio depends only on the heating values and densities, which official texts print. The tank ratio adds the filling limit, and the hull space adds the space factor, both of which depend on the design, so the page leaves them to you.

Your comparison step by step

  1. Reference fuel: 2,000 m³ × 0.98 = 1,960.0 m³, × 0.991 t/m³ = 1,942.36 t.
  2. Energy: 1,942.36 t × 40.2 GJ/t = 78,082.9 GJ.
  3. Ammonia, refrigerated: 78,082.9 GJ ÷ 18.6 GJ/t = 4,198.00 t; ÷ 0.6816 t/m³ = 6,159.0 m³ of liquid.
  4. Ratios: mass 4,198.00 ÷ 1,942.36 = 2.161; volume 6,159.0 ÷ 1,960.0 = 3.142.
  5. Tank: 6,159.0 ÷ 0.9800 = 6,284.7 m³; × 1.00 space factor = 6,284.7 m³; ÷ 2,000.0 = 3.142.
  6. Endurance: 30.0 t/day × 40.2 = 1,206.0 GJ/day. The 2,000 m³ tank holds 78,082.9 GJ of VLSFO (64.75 days) or 2,000 × 0.98 × 0.6816 × 18.6 = 24,848.4 GJ of ammonia, refrigerated (20.60 days).

Regulatory basis

The IMO heating values are MEPC.364(79) paragraph 2.2.1 and MEPC.391(81) Appendix 2, with ethanol in MEPC.1/Circ.926;1,2,14 the EU values are Regulation (EU) 2023/1805 Annex II with RED Annex III for liquid biofuels.3,13 Filling limits are IGF Code 6.8 and the interim guidelines for ammonia, hydrogen, alcohols and LPG.5,7,8,9,10

IMO heating values
MEPC.364(79) 2.2.1: HFO 40,200, LFO 41,200, MGO 42,700, LNG 48,000, propane 46,300, butane 45,700, methanol 19,900, ethanol 26,800 kJ/kg; amended by MEPC.410(84), table unchanged1
IMO, newer fuels
MEPC.391(81) Appendix 2: ammonia 0.0186, hydrogen 0.12, HVO 0.044, FAME 0.0372 MJ/g; HFO(VLSFO) 0.04022
FuelEU Maritime
Annex II: HFO 0.0405, LNG 0.0491, LPG 0.046 MJ/g; liquid biofuels from RED Annex III, HVO 44, FAME 37, ethanol 27 MJ/kg3,13
EEDI densities
Heavy fuel oil 991, diesel or gas oil 900, LNG 450 kg/m³; filling rate 0.98, 0.98 and 0.95, MEPC.411(84) 4.2.3.24
Filling limit
98% at the reference temperature; loading limit LL = FL × ρR ÷ ρL; never above 95% under the relaxation, IGF Code 6.8.1 to 6.8.35,6
Ammonia
Stored refrigerated at atmospheric pressure; 98% filling limit, MSC.1/Circ.1687 6.3.1 and 6.8.17
Hydrogen
Vacuum-insulated type C independent tanks only; IGF Code 6.8 applies, MSC.1/Circ.1701 6.4.2 and 6.8.18
Methanol, ethanol
No numeric filling limit; cofferdams around integral tanks, 600 mm to category A machinery spaces, MSC.1/Circ.1621 5.3.2 and 11.4.39
LPG
IGF Code chapter 6 applies unless stated otherwise, 6.8 included, MSC.1/Circ.1666 6.3.110

What the tank figures leave out

  • Space factor. No IMO, EU or IACS text gives the hull space a type A, B, C, membrane or integral tank takes per m³ of fuel; the calculator applies 1 until you enter your design’s figure.
  • Densities at one condition. Each density holds at the temperature printed beside it; a warmer LNG, a lighter VLSFO or a different ammonia storage pressure changes the volume in proportion.4,11
  • Equal energy, not equal range. Engine efficiency on the new fuel is your input; boil-off, unpumpable residue, settling and service tanks are not modeled.
  • Pilot fuel from the maker. The share is your engine’s figure; the makers print it at stated load points, some by energy and some by mass.16,17,18
  • Not emissions. Well-to-wake GHG intensity and FuelEU compliance are separate calculations; this page sizes tanks only.

Frequently Asked Questions (FAQs)

How much bigger is an ammonia tank than a VLSFO tank?

For the same energy, refrigerated ammonia at 18.6 MJ/kg and 681.6 kg/m³ takes 3.14 times the liquid volume of VLSFO at 40.2 MJ/kg and 991 kg/m³, using the IMO heating values in MEPC.364(79) and MEPC.391(81). A 2,000 m³ VLSFO tank filled to 98% becomes 6,159 m³ of ammonia and a 6,285 m³ tank at the same filling limit, before any allowance for insulation or tank shape.

What is the energy density of ammonia?

Ammonia's lower calorific value is 18.6 MJ/kg in IMO resolution MEPC.391(81) and in FuelEU Maritime Annex II. Liquid ammonia at −33.3 °C and atmospheric pressure has a density of 681.6 kg/m³ (NIST), so it holds 12.7 GJ/m³ (12.7 MJ/L), against 39.8 GJ/m³ for a fuel oil at 40.2 MJ/kg and 991 kg/m³. Pressurized at 25 °C it is 603.0 kg/m³ and 11.2 GJ/m³.

How many tonnes of methanol equal one tonne of VLSFO?

2.02 tonnes, from the lower calorific values 40.2 MJ/kg for VLSFO and 19.9 MJ/kg for methanol in IMO resolution MEPC.364(79). By volume, at 991 and 791.0 kg/m³, one cubic meter of VLSFO is replaced by 2.53 m³ of methanol.

Is the LNG heating value 48 or 49.1 MJ/kg?

Both are official. IMO resolution MEPC.364(79) and MEPC.391(81) give LNG 48.0 MJ/kg; FuelEU Maritime, Regulation (EU) 2023/1805 Annex II, gives 0.0491 MJ/g, which is 49.1 MJ/kg. The EU figure needs 2.2% less LNG for the same energy. Use the IMO figure for EEDI and EEXI work and the EU figure for a FuelEU report.

What filling limit applies to LNG and ammonia fuel tanks?

IGF Code paragraph 6.8.1 says liquefied gas fuel tanks shall not be filled to more than 98% full at the reference temperature, and gives the loading limit LL = FL × ρR ÷ ρL for the actual loading temperature. MSC.1/Circ.1687 applies the same 98% to ammonia, MSC.1/Circ.1701 to liquid hydrogen and MSC.1/Circ.1666 to LPG. For the EEDI, MEPC.411(84) uses a filling rate of 0.95 for LNG.

Is there a filling limit for methanol fuel tanks?

Not as a number. MSC.1/Circ.1621, the interim guidelines for methyl and ethyl alcohol fuels, sets no filling limit for integral fuel tanks; it requires cofferdams around them and at least 600 mm between the tanks and category A machinery spaces (paragraph 11.4.3). The 98% used here for methanol is the MEPC.411(84) figure for oil tanks, applied as a convention.

How much pilot fuel does a dual-fuel engine burn?

It depends on the engine. Everllence (formerly MAN Energy Solutions) states a pilot oil energy fraction as low as 1.5% at 100% load for some ME-GI bore sizes; WinGD gives 0.5 to 1% of total energy for its low-pressure X-DF engines; Wärtsilä states a 95% ammonia energy share for the Wärtsilä 25 Ammonia, leaving about 5% pilot. These are maker's figures at stated load points, so enter your engine's figure.

Which alternative fuel needs the most tank space?

Liquid hydrogen. At 120 MJ/kg and 70.8 kg/m³ at −252.9 °C it takes 4.69 times the liquid volume of VLSFO for the same energy, against 3.14 for refrigerated ammonia, 2.53 for methanol and 1.84 for LNG. MSC.1/Circ.1701 covers it only in vacuum-insulated type C tanks, which add more hull space again.

How to use this calculator

  1. Choose where to start: a tank of the reference fuel in cubic meters, the tonnes bunkered, or a voyage as tonnes a day for a number of days. Enter the daily consumption in every case; it gives the endurance.
  2. Pick the reference fuel, VLSFO, HFO or MGO, and check its density against the bunker delivery note at 15 °C and its filling limit against the tank plan.
  3. Pick the fuel to compare. Its heating value, its density at the temperature shown and its default filling limit fill in; change the density or the filling limit to your design's figures, or work the IGF Code loading limit from the relief valve setting.
  4. Enter a space factor for the tank arrangement if you have one from your design, the pilot fuel share from the engine maker's data, and the engine's efficiency on the new fuel against the old if it differs.
  5. Read the liquid volume and mass, the ratios against the reference fuel, the tank at its filling limit, the hull space and the days the same tank would last. Switch to the FuelEU heating values or to US units if you need them.

Test cases this calculator passes

Every build of this site runs these cases through the calculator above and stops the release if any figure moves outside its tolerance. Load a case to put its inputs into the calculator.

InputsExpected resultTraced toLoad
2,000 m³ VLSFO tank at 98% against refrigerated ammonia, IMO valuesLiquid volume: 6,159 m³Volume ratio: 3.14×Mass: 4,198 tMass ratio: 2.16×Tank at 98% full: 6,285 m³Hull space: 6,285 m³Energy: 78,083 GJSame tank lasts: 20.6 daysMEPC.411(84): 2,000 x 0.98 = 1,960 m3 x 0.991 = 1,942.36 t; MEPC.391(81) Appendix 2 HFO(VLSFO) 40.2 MJ/kg: E = 78,082.9 GJ. MEPC.391(81) NH3 18.6 MJ/kg: 4,198.0 t; NIST 681.6 kg/m3 at -33.3 C: 6,159.0 m3; /0.98 (IGF 6.8.1) = 6,284.7 m3. Ratios 3.142 (40.2 x 991 / 18.6 x 681.6) and 2.161 (40.2/18.6). 30 t/day x 40.2 = 1,206 GJ/day: 64.75 days; 2,000 x 0.98 x 0.6816 x 18.6 = 24,848 GJ: 20.60 days.Load inputs
Methanol for the default tank, no pilot fuelLiquid volume: 4,961 m³Volume ratio: 2.53×Mass: 3,924 tMass ratio: 2.02×Tank at 98% full: 5,062 m³Hull space: 5,062 m³Energy: 78,083 GJSame tank lasts: 25.6 daysMEPC.364(79) methanol 19.9 MJ/kg, NIST 791.0 kg/m3 at 20 C: 78,082.9 / 19.9 = 3,923.8 t, 4,960.5 m3; ratio 2.531 (40.2 x 991 / 19.9 x 791.0).Load inputs
Methanol with 5% of the energy from pilot MGOLiquid volume: 4,712 m³Volume ratio: 2.40×Mass: 3,728 tMass ratio: 1.92×Tank at 98% full: 4,809 m³Hull space: 4,809 m³Energy: 78,083 GJSame tank lasts: 26.9 daysPilot MGO: 91 tMEPC.364(79) methanol 19.9 MJ/kg, NIST 791.0 kg/m3 at 20 C: 78,082.9 x 0.95 / 19.9 = 3,727.6 t, 4,712.5 m3. Pilot 78,082.9 x 0.05 / 42.7 = 91.43 t, /0.9 = 101.6 m3, /0.98 = 103.7 m3. The pilot comes from its own tank, so the same tank lasts 1,960 x 0.791 x 19.9 / (1,206 x 0.95) = 26.93 days.Load inputs
LNG at the MEPC.411(84) filling rate of 0.95Liquid volume: 3,615 m³Volume ratio: 1.84×Mass: 1,627 tMass ratio: 0.84×Tank at 95% full: 3,805 m³Hull space: 3,805 m³Energy: 78,083 GJSame tank lasts: 34.0 daysMEPC.364(79) LNG 48.0 MJ/kg, MEPC.411(84) 450 kg/m3 and 0.95: 1,626.7 t, 3,614.9 m3, tank 3,805.2 m3; volume ratio 1.844.Load inputs
Liquid hydrogen with a space factor of 1.5 typed inLiquid volume: 9,191 m³Volume ratio: 4.69×Mass: 651 tMass ratio: 0.34×Tank at 98% full: 9,378 m³Hull space: 14,067 m³Energy: 78,083 GJSame tank lasts: 13.8 daysMEPC.391(81) H2 0.12 MJ/g, NIST 70.8 kg/m3: 650.7 t, 9,190.5 m3; /0.98 = 9,378.1 m3; x 1.5 = 14,067.2 m3; 7.034 x the VLSFO tank.Load inputs
The other 8 test cases
InputsExpected resultTraced toLoad
Ammonia pressurized at 25 °C, outside the Circ.1687 base caseLiquid volume: 6,962 m³Volume ratio: 3.55×Mass: 4,198 tMass ratio: 2.16×Tank at 98% full: 7,104 m³Hull space: 7,104 m³Energy: 78,083 GJSame tank lasts: 18.2 daysNIST 603.0 kg/m3 at 25 C and 10.0 bar: 4,198.0 t, 6,961.9 m3, ratio 3.552. MSC.1/Circ.1687 6.3.1: refrigerated at atmospheric pressure.Load inputs
LNG on the FuelEU Annex II heating valuesLiquid volume: 3,560 m³Volume ratio: 1.82×Mass: 1,602 tMass ratio: 0.82×Tank at 95% full: 3,748 m³Hull space: 3,748 m³Energy: 78,666 GJSame tank lasts: 34.6 daysReg. (EU) 2023/1805 Annex II: HFO 0.0405, LNG 0.0491 MJ/g. E = 1,942.36 x 40.5 = 78,665.6 GJ; LNG 1,602.2 t, 3,560.3 m3; ratio 1.816.Load inputs
A voyage: 30 t a day of VLSFO for 20 daysLiquid volume: 1,903 m³Volume ratio: 3.14×Mass: 1,297 tMass ratio: 2.16×Tank at 98% full: 1,941 m³Hull space: 1,941 m³Energy: 24,120 GJSame tank lasts: 6.4 days600 t x 40.2 = 24,120 GJ; ammonia 1,296.8 t, 1,902.5 m3; ratio 3.142.Load inputs
Ammonia against an MGO tankLiquid volume: 5,941 m³Volume ratio: 3.03×Mass: 4,050 tMass ratio: 2.30×Tank at 98% full: 6,063 m³Hull space: 6,063 m³Energy: 75,323 GJSame tank lasts: 19.4 daysMEPC.364(79) MGO 42.7 MJ/kg, MEPC.411(84) 900 kg/m3: 2,000 x 0.98 x 0.9 = 1,764 t, 75,322.8 GJ; ammonia 4,049.6 t, 5,941.3 m3; ratio 3.031 (42.7 x 900 / 18.6 x 681.6).Load inputs
The default in US gallons and short tonsLiquid volume: 1,627,047 galMass: 4,628 sh tnEnergy: 74,008 MMBtu6,159.0 m3 x 264.172 = 1,627,047 US gal; 4,198.0 t x 1.10231 = 4,628 short tons; 78,082.9 GJ x 0.947817 = 74,008 MMBtu.Load inputs
Ammonia tank filled to 90%Liquid volume: 6,159 m³Volume ratio: 3.14×Mass: 4,198 tMass ratio: 2.16×Tank at 90% full: 6,843 m³Hull space: 6,843 m³Energy: 78,083 GJSame tank lasts: 18.9 days6,159.0 / 0.90 = 6,843.4 m3; 3.422 x the VLSFO tank.Load inputs
Refused: a filling limit above 98%Shows “Enter a filling limit from 50 to 98%”IGF Code 6.8.1: liquefied gas fuel tanks not filled beyond 98% at the reference temperature.Load inputs
Refused: an empty tank volumeShows “Enter the tank volume from 1 to 100,000 ”A tank of 0 m3 carries no energy.Load inputs

Calculators used with this one

The CII calculator takes the fuel burned in a year and rates the ship’s carbon intensity under MEPC.352(78) to MEPC.355(78).

For the days at sea on a route, the sea distance calculator gives the port-to-port distance with canal and ECA legs.

Change log

Each change to the method, a coefficient or a test case, with the date it reached this page.

  • First published, replacing eight single-fuel property pages: eleven fuels against VLSFO, HFO or MGO on IMO or FuelEU heating values, IGF Code filling limits with the loading limit formula, space factor, pilot fuel, engine efficiency, endurance and US units, with 12 test cases.

Who publishes this calculator and how it is checked

Publisher
ShipCalculators.com, an independent site of maritime calculators.
How it is checked
Each figure is traced to the instrument that sets it, and the test cases on this page run against the calculator code on every build; a build that moves one of them does not deploy. Last method check: 31 October 2026.
What it is not
Not a tank design: the class society approves the fuel containment, the filling and loading limits and the arrangement under the IGF Code or the interim guidelines for the fuel.

Regulation and sources

  1. IMO Resolution MEPC.364(79), 2022 Guidelines on the method of calculation of the attained EEDI for new ships, paragraph 2.2.1, table of Cf and lower calorific values
  2. IMO Resolution MEPC.391(81), 2024 Guidelines on life cycle GHG intensity of marine fuels, Appendix 2, initial default emission factors
  3. Regulation (EU) 2023/1805 on the use of renewable and low-carbon fuels in maritime transport (FuelEU Maritime), Annex II
  4. IMO Resolution MEPC.411(84), 2026 Guidelines on survey and certification of the EEDI, paragraph 4.2.3.2, normal density and filling rate of tanks
  5. IMO Resolution MSC.391(95), International Code of Safety for Ships using Gases or other Low-flashpoint Fuels (IGF Code), paragraphs 2.2.16, 2.2.27, 2.2.36 and 6.8
  6. IMO Resolution MSC.458(101), amendments to the IGF Code adding paragraph 6.8.3, in force 1 January 2024
  7. IMO MSC.1/Circ.1687, Interim guidelines for the safety of ships using ammonia as fuel, 26 February 2025
  8. IMO MSC.1/Circ.1701, Interim guidelines for the safety of ships using hydrogen as fuel, 7 July 2026
  9. IMO MSC.1/Circ.1621, Interim guidelines for the safety of ships using methyl/ethyl alcohol as fuel, 7 December 2020
  10. IMO MSC.1/Circ.1666, Interim guidelines for the safety of ships using LPG fuels, 30 June 2023
  11. NIST Chemistry WebBook, SRD 69, Thermophysical properties of fluid systems: methane, methanol, ammonia, hydrogen, propane and n-butane
  12. PubChem, Ethanol (CID 702), density 0.7893 g/cm³ at 20 °C, US National Library of Medicine
  13. Directive (EU) 2018/2001 (RED), consolidated 16 July 2024, Annex III, energy content of fuels
  14. IMO MEPC.1/Circ.926, List of default emission factors, 29 June 2026
  15. US Department of Energy, NREL, Biodiesel Handling and Use Guidelines, sixth edition (2023), Table 2
  16. Everllence, ME-GI dual-fuel two-stroke engine, pilot oil energy fraction
  17. WinGD, X-DF frequently asked questions, Tables 1 and 2, pilot fuel quantity
  18. Wärtsilä 25 dual-fuel and ammonia engine, ammonia energy share
  19. EMSA, Potential of Ammonia as Fuel in Shipping (2022), Table 11, fuel tank volume compared to MGO
  20. ClassNK, Alternative Fuels Insight, version 2.2 (February 2025), fuel properties overview, as hosted by IMO
  21. MAN Energy Solutions, The methanol-fuelled MAN B&W LGIM engine, pilot oil
  22. Mærsk Mc-Kinney Møller Center for Zero Carbon Shipping, Emerging ship design principles for ammonia-fueled vessels (October 2024), Tables 2 and 4
  23. DNV GL Report No. 2019-0567 Rev. 4, Comparison of Alternative Marine Fuels, for SEA\LNG (25 September 2019), page 28