What is the POLARIS RIO for this ice and this ship?
IMO MSC.1/Circ.1519 Appendix, POLARIS · Risk Index Values of Table 1.3 and the decayed Table 1.4 · the twelve ice classes PC1 to PC7, IA Super to IC and not ice strengthened · Table 1.1 operation levels and Table 1.2 speed limits · escort planning (1.6.4) and entry to a Canadian shipping safety control zone (SOR/2017-286 s. 8(2)) · Updated 15 November 2026
Published by ShipCalculators.com. Method checked against IMO MSC.1/Circ.1519, Appendix (POLARIS), Polar Code, MSC.385(94), Part I-A 1.5 and chapter 12 and Canada SOR/2017-286 ss. 2, 8 and 9 on 15 November 2026. How calculators are checked
Answer
A PC6 ship in 6/10 thick first-year ice and 4/10 thin first-year ice, second stage, has a POLARIS Risk Index Outcome of −2, from 6 × (−1) + 4 × 1 on Table 1.3: elevated operational risk under Table 1.1 of IMO MSC.1/Circ.1519, with a recommended speed limit of 3 knots (Table 1.2).
Change the inputs below to recompute.
Contents22 sections
What POLARIS is
POLARIS, the Polar Operational Limit Assessment Risk Indexing System, is the method in the appendix to IMO circular MSC.1/Circ.1519 of 6 June 2016 for judging whether an ice regime suits a ship’s ice class, as part of the operational limitations the Polar Code requires a ship to assess.1,2 Whether the Polar Code applies to the ship and voyage in the first place is answered by the Polar Code applicability calculator. The circular calls POLARIS a decision support tool, not a Go or No Go tool: the decision stays with the master and the officers qualified under Polar Code chapter 12.
Work out the Risk Index Outcome
A PC6 ship in 6/10 thick first-year ice, 4/10 thin first-year ice, 2nd stage.
RIO −2, elevated operational risk, 3 knots
- Operation
- Elevated operational risk
- Risk Index Outcome
- Speed limit
- RIV table
- Normal from class
- PC5 (RIO 8)Table 1.1
- Margin
- 2 short of normalTable 1.1
- With escort, planning
- 8, normal1.6.4
- Canadian zone entry
- With PWOM, 8(2)(c)s. 8(2)
Table 1.2 recommends 3 knots for PC6 (Below PC5); where that speed impairs maneuverability the operation should be avoided (1.4.1), and the PWOM may hold speeds calibrated by ice load monitoring or trials (1.4.2, 1.4.3).
What this RIO means for the ship
RIO −2 for a PC6 ship (4 × 1 + 6 × (−1) = −2, Table 1.3): elevated operational risk under Table 1.1, with a recommended speed limit of 3 knots (Table 1.2).
Every class from PC1 down to PC5 reaches normal operation in this regime on Table 1.3, PC5 with RIO 8.
Elevated operational risk (1.4): limit the speed to Table 1.2, avoid such areas in the voyage plan where possible, and document contingency plans in the PWOM where they are included (1.4.5).
- Table 1.2 recommends 3 knots for PC6 (Below PC5); where that speed impairs maneuverability the operation should be avoided (1.4.1), and the PWOM may hold speeds calibrated by ice load monitoring or trials (1.4.2, 1.4.3).
Cite or share this calculation
ShipCalculators.com, “POLARIS Calculator: Risk Index Outcome (RIO) for Ice.” Method: IMO MSC.1/Circ.1519, Appendix 1.2.2, Tables 1.1, 1.2 and 1.3. Inputs: A PC6 ship in 6/10 thick first-year ice, 4/10 thin first-year ice, 2nd stage. Result: RIO −2, elevated operational risk, 3 knots. https://shipcalculators.com/calculators/polaris
The citation names ShipCalculators.com as publisher; copying it adds today's date.
Working out the RIO by hand
Under MSC.1/Circ.1519, the Risk Index Outcome of an ice regime is each ice type’s concentration in tenths times its Risk Index Value for the ship’s ice class, added up, with the ice-free share counted at 3. A RIO of 0 or more is normal operation. From −10 to below 0 a Polar Class PC1 to PC7 ship is at elevated operational risk and keeps to 11, 8, 5 or 3 knots by class; any other ship is subject to special consideration below 0, and every ship below −10.
Drawings of your result
The ice regime in tenths
Each cell is one tenth of the sea surface, shaded by ice type and carrying its Risk Index Value; the codes under the cells are the egg code stages (IF ice-free).
The Risk Index Outcome on Table 1.1
This ship's row of Risk Index Values
The same ice for every ice class
The regime as an egg code, and the speed limits
RIO −2 for a PC6 ship (4 × 1 + 6 × (−1) = −2, Table 1.3): elevated operational risk under Table 1.1, with a recommended speed limit of 3 knots (Table 1.2).
Formula, assumptions, and limits
POLARIS reduces an ice regime and a ship’s ice class to one integer, the Risk Index Outcome, and reads that integer against two thresholds. The arithmetic is a weighted sum in tenths; the judgment sits in which column of the table each ice type falls into.
Formula
POLARIS Risk Index Outcome
MSC.1/Circ.1519, Appendix 1.2.2:
Where, Table 1.1, normal operation:
Elevated operational risk, PC1 to PC7 only; otherwise special consideration:
where
| Risk Index Outcome of one ice regime, an integer from −80 to 30 | ||
| concentration of ice type i in tenths, ice-free water included, adding up to 10 | tenths | |
| Risk Index Value of ice type i for the ship’s ice class, Table 1.3, or Table 1.4 when decay is confirmed | ||
| number of ice types in the regime |
Derivation
- The ice regime. The annex defines an ice regime as “a description of an area with a relatively consistent distribution of any mix of ice types, including open water”. The calculator enters the tenths the ice does not cover as ice-free, so the concentrations always add up to 10.1
- The column. Each ice type reads one of the twelve columns of Table 1.3. Medium first-year ice reads the heavier column unless its thickness is confirmed under 1 m, and multi-year ice the heavy column unless it is confirmed under 2.5 m (paragraph 1.1.2).
- The table. Table 1.4 replaces Table 1.3 only when ice decay is confirmed by personnel qualified under Polar Code chapter 12 (paragraph 1.1.3).2
- The sum. Each concentration times its value, added: integer inputs give an integer RIO, and nothing is rounded.
- The level. Table 1.1 has two columns: PC1 to PC7, and every class below PC7 together with ships with no ice class. For the first, −10 to below 0 is elevated operational risk; for the second, any RIO below 0 is operation subject to special consideration.
- The speed. At elevated operational risk, Table 1.2 gives the recommended speed limit by ice class.
Assumptions
- The ice class is the one referenced in the Polar Ship Certificate (Appendix II); a class society notation outside the twelve rows has to be read through that certificate’s equivalence, which the calculator does not map.
- Concentrations are whole tenths. A trace, under 1/10, cannot be entered and is not counted; the circular says nothing about traces.
- The regime is one area of consistent ice. A route through several regimes has one RIO per regime, and the circular sets no rule for averaging them.
Worked example
A PC6 ship meets an ice regime of 6/10 thick first-year ice and 4/10 thin first-year ice, second stage, with no open water.
- Table 1.3, PC6 row: thick first-year ice −1, thin first-year ice second stage 1.
- RIO = 6 × (−1) + 4 × 1 = −6 + 4 = −2.
- Table 1.1, PC1 to PC7 column: −10 ≤ −2 < 0, elevated operational risk.
- Table 1.2, below PC5: a recommended speed limit of 3 knots.
- With 9/10 thick first-year ice and 1/10 second-year ice instead, RIO = 9 × (−1) + 1 × (−2) = −11, special consideration; a voyage plan with an icebreaker escort may take −11 + 10 = −1 (paragraph 1.6.4).
Edge cases and limits
- RIO of exactly 0. Normal operation: Table 1.1 reads “RIO ≥ 0”. A PC7 ship in 5/10 medium first-year ice and 5/10 thin first-year ice second stage scores 5 × (−1) + 5 × 1 = 0.
- RIO of exactly −10. Elevated operational risk for PC1 to PC7, special consideration for every other ship. A PC5 ship in 10/10 second-year ice scores −10 and keeps 5 knots.
- PC1 to PC3. PC1 and PC2 cannot score below 0 on Table 1.3, and PC3 cannot score below −10, because their lowest values are 1, 0 and −1.
- No ice class. 10/10 heavy multi-year ice gives the lowest possible RIO, 10 × (−8) = −80.
- Over 10 tenths. Concentrations adding up to more than 10 are refused: concentration is the share of the sea surface in tenths (WMO-No. 259, 4.2).6
Regulatory basis
The Polar Code, adopted by MSC.385(94), requires operational limitations in ice to be assessed (Part I-A 1.5) and stated in the Polar Ship Certificate; MSC.1/Circ.1519 of 6 June 2016 gives the guidance and, in its appendix, POLARIS.1,2 The circular calls itself interim guidance to be reviewed four years after the Code entered into force. That review has not been completed: a POLARIS project approved by the Arctic Council’s PAME working group in November 2024 held its first correspondence group meeting on 15 January 2025.8
Common errors
- Fractions instead of tenths. A concentration entered as 0.6 rather than 6 scales the RIO down tenfold against thresholds of 0 and −10 that are set for tenths.
- Reading −10 as a stop. Annex paragraph 1.4 says POLARIS “should not be interpreted as a ‘Go/No Go’ tool but as a decision support tool”; special consideration calls for extreme caution, re-routing and further speed reduction under the PWOM.
- One speed for every class. Table 1.2 gives four speeds, 11, 8, 5 and 3 knots, by class; 8 knots is the PC2 figure only.
- The PC column for a Finnish-Swedish class. IA Super to IC sit in Table 1.1’s right-hand column with ships of no ice class, so a RIO of −5 is special consideration for an IA Super ship and elevated risk for a PC6 ship.
- Using the lighter columns by default. The medium first-year ice under 1 m and light multi-year ice columns need a confirmed thickness; the default is the heavier column.
POLARIS Table 1.3, Risk Index Values
Reproduced from MSC.1/Circ.1519, Appendix, Table 1.3, as printed. Columns: ice-free (IF), new ice, grey ice, grey-white ice (GW), thin first-year ice 1st and 2nd stage (TFY1, TFY2), medium first-year ice less than 1 m thick (MFY <1 m), medium first-year ice (MFY), thick first-year ice (TkFY), second-year ice (SY), light multi-year ice less than 2.5 m thick (LMY) and heavy multi-year ice (HMY).1
Ice-free to thin first-year ice:
| Ice class | IF | New | Grey | GW | TFY1 | TFY2 |
|---|---|---|---|---|---|---|
| PC1 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC2 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC3 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC4 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC5 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC6 | 3 | 2 | 2 | 2 | 2 | 1 |
| PC7 | 3 | 2 | 2 | 2 | 1 | 1 |
| IA Super | 3 | 2 | 2 | 2 | 2 | 1 |
| IA | 3 | 2 | 2 | 2 | 1 | 0 |
| IB | 3 | 2 | 2 | 1 | 0 | −1 |
| IC | 3 | 2 | 1 | 0 | −1 | −2 |
| Not Ice Strengthened | 3 | 1 | 0 | −1 | −2 | −3 |
Medium first-year to multi-year ice:
| Ice class | MFY <1 m | MFY | TkFY | SY | LMY | HMY |
|---|---|---|---|---|---|---|
| PC1 | 2 | 2 | 2 | 2 | 1 | 1 |
| PC2 | 2 | 2 | 2 | 1 | 1 | 0 |
| PC3 | 2 | 2 | 2 | 1 | 0 | −1 |
| PC4 | 2 | 2 | 1 | 0 | −1 | −2 |
| PC5 | 1 | 1 | 0 | −1 | −2 | −2 |
| PC6 | 1 | 0 | −1 | −2 | −3 | −3 |
| PC7 | 0 | −1 | −2 | −3 | −3 | −3 |
| IA Super | 0 | −1 | −2 | −3 | −4 | −4 |
| IA | −1 | −2 | −3 | −4 | −5 | −5 |
| IB | −2 | −3 | −4 | −5 | −6 | −6 |
| IC | −3 | −4 | −5 | −6 | −7 | −8 |
| Not Ice Strengthened | −4 | −5 | −6 | −7 | −8 | −8 |
POLARIS Table 1.4, decayed ice conditions
Table 1.4 differs from Table 1.3 in three columns only: for PC5 and every class below it, the medium first-year ice under 1 m, medium first-year ice and thick first-year ice values are 1 higher. PC1 to PC4 are unchanged, and so is every second-year and multi-year value. The PC6 row then reads 2 for medium first-year ice under 1 m, above its 1 for thin first-year ice second stage; that is the printed value and the calculator uses it.1
Ice-free to thin first-year ice:
| Ice class | IF | New | Grey | GW | TFY1 | TFY2 |
|---|---|---|---|---|---|---|
| PC1 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC2 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC3 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC4 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC5 | 3 | 3 | 3 | 3 | 2 | 2 |
| PC6 | 3 | 2 | 2 | 2 | 2 | 1 |
| PC7 | 3 | 2 | 2 | 2 | 1 | 1 |
| IA Super | 3 | 2 | 2 | 2 | 2 | 1 |
| IA | 3 | 2 | 2 | 2 | 1 | 0 |
| IB | 3 | 2 | 2 | 1 | 0 | −1 |
| IC | 3 | 2 | 1 | 0 | −1 | −2 |
| Not Ice Strengthened | 3 | 1 | 0 | −1 | −2 | −3 |
Medium first-year to multi-year ice:
| Ice class | MFY <1 m | MFY | TkFY | SY | LMY | HMY |
|---|---|---|---|---|---|---|
| PC1 | 2 | 2 | 2 | 2 | 1 | 1 |
| PC2 | 2 | 2 | 2 | 1 | 1 | 0 |
| PC3 | 2 | 2 | 2 | 1 | 0 | −1 |
| PC4 | 2 | 2 | 1 | 0 | −1 | −2 |
| PC5 | 2 | 2 | 1 | −1 | −2 | −2 |
| PC6 | 2 | 1 | 0 | −2 | −3 | −3 |
| PC7 | 1 | 0 | −1 | −3 | −3 | −3 |
| IA Super | 1 | 0 | −1 | −3 | −4 | −4 |
| IA | 0 | −1 | −2 | −4 | −5 | −5 |
| IB | −1 | −2 | −3 | −5 | −6 | −6 |
| IC | −2 | −3 | −4 | −6 | −7 | −8 |
| Not Ice Strengthened | −3 | −4 | −5 | −7 | −8 | −8 |
Operation levels and speed limits
Table 1.1 sets the level from the RIO and the ice class; Table 1.2 sets the speed for elevated risk.1
| RIO | PC1 to PC7 | Below PC7 and no ice class |
|---|---|---|
| 0 and above | Normal operation | Normal operation |
| −10 to below 0 | Elevated operational risk | Operation subject to special consideration |
| Below −10 | Operation subject to special consideration | Operation subject to special consideration |
| Ice class | Recommended speed limit, elevated risk |
|---|---|
| PC1 | 11 knots |
| PC2 | 8 knots |
| PC3 to PC5 | 5 knots |
| Below PC5 | 3 knots |
Where the reduced speed would impair the ship’s maneuverability, paragraph 1.4.1 says the operation should be avoided, and paragraphs 1.4.2 and 1.4.3 allow the speeds to be calibrated from ice load monitoring, full-scale trials or calculation, with the result recorded in the Polar Water Operational Manual.
Ice types, WMO stages and the egg code
POLARIS follows the WMO sea-ice nomenclature except that it splits medium first-year ice and multi-year ice by thickness. An ice chart gives the regime as an egg: total concentration Ct, partial concentrations Ca, Cb and Cc in tenths, thickest first, and their stages Sa, Sb and Sc.6,7
| POLARIS column | WMO-No. 259 stage and thickness | Egg code stage |
|---|---|---|
| New ice | New ice: frazil, grease, slush, shuga | 1 |
| Grey ice | Grey ice, 10 to 15 cm | 4 |
| Grey-white ice | Grey-white ice, 15 to 30 cm | 5 |
| Thin first-year ice, 1st stage | 30 to 50 cm | 8 |
| Thin first-year ice, 2nd stage | 50 to 70 cm | 9 |
| Medium first-year ice | 70 to 120 cm; under 1 m only when confirmed | 1• |
| Thick first-year ice | over 120 cm | 4• |
| Second-year ice | up to 2.5 m and sometimes more | 8• |
| Multi-year ice | up to 3 m or more; under 2.5 m only when confirmed | 9• |
Codes 8 and 9 for the two thin first-year stages are from TP 12259E Table 1.5 Generic codes on a chart, such as 3 for young ice, 7 for thin first-year ice and 7• for old ice, have no single POLARIS column. The cautious reading takes the thicker stage: grey-white ice for young ice, thin first-year ice second stage for code 7 and heavy multi-year ice for old ice.
POLARIS in Canada’s Arctic regulations
SOR/2017-286 defines POLARIS by reference to the appendix of MSC.1/Circ.1519 and applies it in shipping safety control zones to vessels of 300 GT or more, vessels carrying pollutants or dangerous goods, combined tows of 500 GT or more and SOLAS passenger vessels (s. 7).3 Outside its zone/date period a vessel may enter a zone under s. 8(2) when:
- (a) the AIRSS Ice Numeral is 0 or more, for a vessel built before 1 January 2017 that is not Polar Class;
- (b) the POLARIS RIO indicates normal operation; or
- (c) for Polar Class 3 to 7, the RIO indicates elevated operational risk, the Polar Waters Operations Manual has measures for it and the vessel follows them.
Section 9 adds a message to the Minister before entry, with each anticipated ice regime and its RIO, and an acknowledgement. The 2018 Regulatory Impact Analysis Statement says Polar Class vessels and vessels built after 1 January 2017 use POLARIS rather than having the choice of AIRSS.4
Your RIO step by step
- Ice class: PC6, Table 1.3, standard values.
- Ice regime: 6/10 thick first-year ice, 4/10 thin first-year ice, 2nd stage; the ice covers 10/10, so 0/10 is entered as ice-free.
- Thin first-year ice, 2nd stage: 4 × 1 = 4.
- Thick first-year ice: 6 × (−1) = −6.
- RIO = 4 + −6 = −2.
- Table 1.1, PC1 to PC7 column: elevated operational risk; Table 1.2, Below PC5: 3 knots.
Regulatory basis
The Polar Code, adopted by IMO Resolution MSC.385(94) and mandatory under SOLAS chapter XIV from 1 January 2017, requires an assessment of operational limitations in ice for the Polar Ship Certificate (Part I-A 1.5); MSC.1/Circ.1519 of 6 June 2016 gives the guidance for it, with POLARIS as its appendix.1,2 Canada’s Arctic Shipping Safety and Pollution Prevention Regulations, SOR/2017-286, define POLARIS by reference to that appendix and use the RIO for entering a shipping safety control zone.3
- Formula
- RIO = sum of concentration in tenths × RIV, Appendix 1.2.21
- Values
- Table 1.3 standard; Table 1.4 when decay is confirmed by chapter 12 personnel, 1.1.31
- Columns
- Medium first-year under 1 m and light multi-year under 2.5 m only when the thickness is confirmed, 1.1.21
- Levels
- Normal from 0; elevated −10 to below 0 for PC1 to PC7; special consideration otherwise, Table 1.11
- Speeds
- PC1 11 knots, PC2 8, PC3 to PC5 5, below PC5 3, elevated risk only, Table 1.21
- Escort
- +10 for voyage planning from historical ice data only; unmodified under escort, 1.61
- Glacial ice
- Outside the RIO; a stand-off distance recorded in the PWOM, 1.71
- Canada
- Zone entry outside the zone/date period on normal operation, or PC3 to PC7 at elevated risk with PWOM measures, SOR/2017-286 s. 8(2)3
What the calculator does not decide
- One RIO per ice regime. A route through several regimes has one RIO for each; the calculator does not combine them, and the circular gives no rule for doing so.
- Concentrations are whole tenths. A trace under 1/10, a chart’s 9+ and the residual stage Sd of an egg code are not entered; read them from the ice chart conventions the ice service uses.
- Glacial ice, ridging, floe size, pressure, visibility and sea state are outside the RIO. Glacial ice needs the stand-off distance recorded in the PWOM (1.7.3).
- The decayed values of Table 1.4 and the lighter thickness columns depend on what personnel qualified under Polar Code chapter 12 can confirm on board; the calculator takes the reader’s word for it.
- Class notations outside the twelve rows, such as Russian Arc classes or Canadian CAC classes, are not mapped. Use the ice class referenced in the Polar Ship Certificate.
- The values are those of MSC.1/Circ.1519 of 6 June 2016, issued as interim guidance and not revised; a review is being prepared under an Arctic Council PAME project approved in November 2024.
- The Canadian row covers SOR/2017-286 s. 8(2) only. The zone/date schedule, AIRSS for older vessels, the message to the Minister of s. 9 and the ice navigator of s. 10 are outside the calculator.
Frequently Asked Questions (FAQs)
How do you calculate the POLARIS RIO?
MSC.1/Circ.1519, Appendix paragraph 1.2.2: multiply the concentration of each ice type in the regime, in tenths, by its Risk Index Value for the ship's ice class from Table 1.3, and add the products, ice-free water included.
A PC6 ship in 6/10 thick first-year ice and 4/10 thin first-year ice second stage has 6 × (−1) + 4 × 1 = −2.
What does a negative RIO mean?
Under Table 1.1, a RIO of 0 or more is normal operation.
From −10 to below 0 it is elevated operational risk for Polar Class PC1 to PC7, and operation subject to special consideration for IA Super, IA, IB, IC and ships with no ice class. Below −10 it is special consideration for every ship.
What speed limit applies at elevated operational risk?
Table 1.2 recommends 11 knots for PC1, 8 knots for PC2, 5 knots for PC3 to PC5 and 3 knots below PC5.
PC1 and PC2 never reach elevated risk on Table 1.3, because their lowest Risk Index Values are 1 and 0, so in practice the limits used are 5 knots for PC3 to PC5 and 3 knots for PC6 and PC7.
When can the decayed ice table be used?
Only when ice decay is confirmed by ice information or visual observation by personnel on board qualified under Polar Code chapter 12 (paragraph 1.1.3).
Table 1.4 adds 1 to the medium and thick first-year values for PC5 and every lower class, and changes nothing for PC1 to PC4.
Does an icebreaker escort add 10 to the RIO?
Only in voyage planning from historical ice data, under paragraph 1.6.4, which calls the +10 an average that can vary.
Under escort the RIO is not modified: the ice regime is the ice immediately ahead, the icebreaker's track plus any unbroken ice out to the escorted ship's beam (1.6.1).
Is POLARIS mandatory?
POLARIS, the Polar Operational Limit Assessment Risk Indexing System, is guidance: the circular calls it a decision support tool, not a Go or No Go tool.
Canada's Arctic Shipping Safety and Pollution Prevention Regulations, SOR/2017-286 s. 8(2), use the POLARIS RIO for entry to a shipping safety control zone outside its zone/date period, and the Polar Ship Certificate names the system the ship's operational limitations are based on.
What is the difference between POLARIS and AIRSS?
Both multiply concentration in tenths by a value per ice type.
Canada's AIRSS (TP 12259E) uses Ice Multipliers for the vessel's Canadian class or type, summed into an Ice Numeral and adjusted for ridging; POLARIS uses Risk Index Values for the twelve Polar Class and Finnish-Swedish rows. Under SOR/2017-286 s. 8(2), AIRSS is open only to vessels built before 1 January 2017 that are not Polar Class.
Can a ship with no ice class use POLARIS?
Yes: Table 1.3 has a row for ships not ice strengthened, running from 3 in ice-free water to −8 in multi-year ice, and Table 1.1 treats any negative RIO for such a ship as operation subject to special consideration.
Annex paragraph 4.4 also allows measures that keep the ship out of contact with ice instead.
No question matches. Try a shorter or different word.
How to use this calculator
- Pick the ice class referenced in the Polar Ship Certificate: PC1 to PC7, IA Super, IA, IB, IC, or not ice strengthened.
- Enter the partial concentration of each ice type in whole tenths, from the ice chart's egg code or from observation; the tenths not covered by ice count as ice-free.
- Say whether the medium first-year ice is confirmed under 1 m thick and the multi-year ice under 2.5 m; without confirmation the heavier columns apply.
- Say whether ice decay is confirmed by personnel qualified under Polar Code chapter 12, which switches to the decayed values of Table 1.4.
- For a voyage plan with an icebreaker escort, or a Canadian shipping safety control zone, switch those on to see the planning RIO and the SOR/2017-286 route.
- Read the RIO, the operation level, the speed limit and the other ice classes, and copy the link to keep the inputs.
Test cases this calculator passes
Every build of this site runs these cases through the calculator above and stops the release if any figure moves outside its tolerance. Load a case to put its inputs into the calculator.
| Inputs | Expected result | Traced to | Load |
|---|---|---|---|
| Default: PC6, 6/10 thick first-year ice, 4/10 thin first-year ice 2nd stage | Operation: Elevated operational riskRisk Index Outcome: −2Speed limit: 3RIV table: 1.3Normal from class: PC5 (RIO 8)Margin: 2 short of normalWith escort, planning: 8, normalCanadian zone entry: With PWOM, 8(2)(c) | 6×(−1) + 4×1 = −2; Table 1.1 PC column −10 ≤ RIO < 0 elevated; Table 1.2 below PC5 3 knots. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC6, 7/10 thin first-year 1st stage, 2/10 medium first-year (thickness not confirmed), 1/10 ice-free | Operation: Normal operationRisk Index Outcome: 17Speed limit: NoRIV table: 1.3Normal from class: IA (RIO 6)Margin: 17 above the 0 limitWith escort, planning: 27, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | 7×2 + 2×0 + 1×3 = 17, normal. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC6, 9/10 thick first-year, 1/10 second-year, escort planning | Operation: Special considerationRisk Index Outcome: −11Speed limit: CutRIV table: 1.3Normal from class: PC4 (RIO 9)Margin: 1 short of elevatedWith escort, planning: −1, elevated riskCanadian zone entry: Not under 8(2) | 9×(−1) + 1×(−2) = −11, special consideration; 1.6.4 planning −11 + 10 = −1, elevated. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| Not ice strengthened, the ice of the PC6 normal case | Operation: Special considerationRisk Index Outcome: −21Speed limit: CutRIV table: 1.3Normal from class: IA (RIO 6)Margin: 21 short of normalWith escort, planning: −11, special considerationCanadian zone entry: Not under 8(2) | 7×(−2) + 2×(−5) + 1×3 = −21, special consideration. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| Not ice strengthened, 5/10 grey-white, 3/10 thin first-year 1st stage, 2/10 ice-free | Operation: Special considerationRisk Index Outcome: −5Speed limit: CutRIV table: 1.3Normal from class: IC (RIO 3)Margin: 5 short of normalWith escort, planning: 5, normalCanadian zone entry: Not under 8(2) | 5×(−1) + 3×(−2) + 2×3 = −5; right-hand column of Table 1.1: special consideration. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
The other 11 test cases
| Inputs | Expected result | Traced to | Load |
|---|---|---|---|
| IA Super, 6/10 medium first-year, 3/10 thick first-year, 1/10 ice-free | Operation: Special considerationRisk Index Outcome: −9Speed limit: CutRIV table: 1.3Normal from class: PC6 (RIO 0)Margin: 9 short of normalWith escort, planning: 1, normalCanadian zone entry: Not under 8(2) | 6×(−1) + 3×(−2) + 1×3 = −9; below PC7: special consideration. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| IA Super, same ice, decay confirmed (Table 1.4) | Operation: Normal operationRisk Index Outcome: 0Speed limit: NoRIV table: 1.4Normal from class: IA Super (RIO 0)Margin: At the limit, RIO 0With escort, planning: 10, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | 6×0 + 3×(−1) + 1×3 = 0, normal (1.1.3). (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC6, 6/10 medium first-year confirmed under 1 m, 4/10 thin first-year 2nd stage | Operation: Normal operationRisk Index Outcome: 10Speed limit: NoRIV table: 1.3Normal from class: IA Super (RIO 4)Margin: 10 above the 0 limitWith escort, planning: 20, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | 6×1 + 4×1 = 10 (1.1.2). (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC6, the same, decay confirmed | Operation: Normal operationRisk Index Outcome: 16Speed limit: NoRIV table: 1.4Normal from class: IA (RIO 0)Margin: 16 above the 0 limitWith escort, planning: 26, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | 6×2 + 4×1 = 16; Table 1.4 PC6 MFY<1m = 2 as printed. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC7, 5/10 medium first-year, 5/10 thin first-year 2nd stage | Operation: Normal operationRisk Index Outcome: 0Speed limit: NoRIV table: 1.3Normal from class: IA Super (RIO 0)Margin: At the limit, RIO 0With escort, planning: 10, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | 5×(−1) + 5×1 = 0; Table 1.1 RIO ≥ 0 normal. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC5, 10/10 second-year ice | Operation: Elevated operational riskRisk Index Outcome: −10Speed limit: 5RIV table: 1.3Normal from class: PC4 (RIO 0)Margin: 10 short of normalWith escort, planning: 0, normalCanadian zone entry: With PWOM, 8(2)(c) | 10×(−1) = −10, elevated; Table 1.2 PC3-PC5 5 knots. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC4, 5/10 multi-year (heavy), 5/10 second-year, Canadian zone | Operation: Elevated operational riskRisk Index Outcome: −10Speed limit: 5RIV table: 1.3Normal from class: PC3 (RIO 0)Margin: 10 short of normalWith escort, planning: 0, normalCanadian zone entry: With PWOM, 8(2)(c) | Table 1.3 PC4: 5×(−2) + 5×0 = −10, elevated; SOR/2017-286 s. 8(2)(c) Polar Class 3 to 7 with PWOM measures. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| 10/10 ice-free | Operation: Normal operationRisk Index Outcome: 30Speed limit: NoRIV table: 1.3Normal from class: Any, even no ice classMargin: 30 above the 0 limitWith escort, planning: 40, normalCanadian zone entry: Allowed after s. 9 message, 8(2)(b) | Table 1.3 IF column 3 for every class: 10×3 = 30. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| Not ice strengthened, 10/10 heavy multi-year ice | Operation: Special considerationRisk Index Outcome: −80Speed limit: CutRIV table: 1.3Normal from class: PC2 (RIO 0)Margin: 80 short of normalWith escort, planning: −70, special considerationCanadian zone entry: Not under 8(2) | Table 1.3: 10×(−8) = −80, the lowest RIO. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| PC7, 4/10 thin first-year 1st stage, 6/10 medium first-year | Operation: Elevated operational riskRisk Index Outcome: −2Speed limit: 3RIV table: 1.3Normal from class: PC6 (RIO 8)Margin: 2 short of normalWith escort, planning: 8, normalCanadian zone entry: With PWOM, 8(2)(c) | Table 1.3: PC7 4×1 + 6×(−1) = −2, elevated, 3 knots; IA Super 4×2 + 6×(−1) = 2, normal; PC6 4×2 + 6×0 = 8. Table 1.3 is not monotonic between PC7 and IA Super. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
| Ice adding up to 12 tenths | Error: The ice concentrations add up to 12 tenths; an ice regime holds at most 10 tenths. | WMO-No. 259 4.2: concentration in tenths of the sea surface; refused. (MSC.1/Circ.1519 Appendix, Tables 1.1 to 1.4) | Load inputs |
Who publishes this calculator and how it is checked
- Publisher
- ShipCalculators.com, an independent site of maritime calculators.
- How it is checked
- Each figure is traced to the instrument that sets it, and the test cases on this page run against the calculator code on every build; a build that moves one of them does not deploy. Last method check: 15 November 2026.
- What it is not
- Not a Go or No Go decision: MSC.1/Circ.1519 annex 1.4 leaves the decision to operate in a given ice regime to personnel on board qualified under Polar Code chapter 12, working to the ship's Polar Water Operational Manual.
Change log
Each change to the method, a coefficient or a test case, with the date it reached this page.
- First published, replacing the POLARIS RIO, POLARIS compute and ice safe speed pages, with Tables 1.3 and 1.4 as printed in MSC.1/Circ.1519, concentrations in tenths, the Table 1.1 column by ice class and the Table 1.2 speeds by class.
Regulation and sources
- IMO MSC.1/Circ.1519, 6 June 2016: Guidance on methodologies for assessing operational capabilities and limitations in ice, Appendix POLARIS, as reproduced by Arctic Council PAME pame.is
- IMO Resolution MSC.385(94), 21 November 2014: International Code for Ships Operating in Polar Waters wwwcdn.imo.org
- Transport Canada, Arctic Shipping Safety and Pollution Prevention Regulations, SOR/2017-286 laws-lois.justice.gc.ca
- Canada Gazette Part II, 10 January 2018: SOR/2017-286 with the Regulatory Impact Analysis Statement gazette.gc.ca
- Transport Canada TP 12259E, Arctic Ice Regime Shipping System (AIRSS) Standard tc.canada.ca
- WMO-No. 259, Sea-Ice Nomenclature, Volume I, Terminology, edition 1970 to 2017, Danish Meteorological Institute copy download.dmi.dk
- Environment and Climate Change Canada, Canadian Ice Service: the egg code for sea ice ice-glaces.ec.gc.ca
- IMO Polar Maritime Seminar 2025, Session 3: POLARIS review, presenters' slides wwwcdn.imo.org
Calculators used with this one
Whether the Polar Code applies to the ship and voyage, and the category its Polar Ship Certificate shows, is on the Polar Code applicability calculator.