ShipCalculators.com

Extended Operational and Trade Vocabulary

Reefer Containers and Cold Chain Logistics glossary

The refrigerated-container and cold-chain vocabulary: A-frame stowage and reefer plug arrangements, active and absorption refrigeration cycles, controlled and modified atmosphere, pre-cooling, and the class guidance for refrigerated cargo. Grounds each term in the reefer machinery or the cold-chain logistics process it belongs to.

253 defined terms.

Showing 250 on this page (page 1 of 2).

A

A-frame stowage
Vessel arrangement on container ships with reefer plugs concentrated in specific bays for power access.
ABS Guide for Refrigerated Cargo
American Bureau of Shipping classification guidance for vessels carrying refrigerated cargo and reefer containers.
Absorption refrigeration
Heat-driven cycle using ammonia-water or lithium bromide-water; rare in marine reefer containers, used in some ship provision plants.
Active reefer
Integral reefer container with onboard refrigeration unit drawing power from ship, terminal, or genset.
Adiabatic cooling
Heat removal by evaporation; pre-cooling technique for some perishable cargoes before stuffing.
Aeration vent
Adjustable fresh-air opening on reefer container for respiring cargo gas exchange.
AHRI 1110
Air-Conditioning, Heating, and Refrigeration Institute standard for performance rating of marine refrigerated container refrigeration units.
Air change rate
Volume of outside air introduced per hour via fresh-air vent, typically 0 to 280 m3/hr on modern reefers.
Air circulation rate
Internal evaporator fan throughput; on a 40RH unit roughly 4,500 to 5,500 m3/hr at high speed.
Air-cooled condenser
Heat exchanger rejecting refrigerant heat to ambient air via condenser fan, standard on container reefer units.
Alarm code
Numeric or alphanumeric fault indication displayed by reefer controller signaling component failure or out-of-range condition.
Ambient temperature
Outside air temperature surrounding the reefer; influences pull-down time and compressor duty cycle.
Ammonia (R717)
Natural refrigerant GWP 0, ODP 0; used in shore cold stores and reefer vessel hold plants, not in container units.
APHIS
Animal and Plant Health Inspection Service, US agency enforcing wood packaging and quarantine rules.
APHIS-PPQ Form 203
USDA Plant Protection and Quarantine notice of arrival and inspection record for treated commodities.
Apples carriage
Typically 0 to -1 C, 90 to 95% RH; long-haul under CA at 2% O2, 1 to 3% CO2.
ASHRAE 15
Safety standard for refrigeration systems, governs refrigerant charge limits and machinery room ventilation.
ASHRAE 34
Refrigerant designation and safety classification standard defining A1, A2L, A3, B1 etc.
Atlantic salmon carriage
Chilled 0 to -1 C, gel-pack or vacuum-pack, typical 14 to 18 day reefer transit.
ATP Agreement
1970 UNECE Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to be Used for Such Carriage.
Avocado carriage
Typically 5 to 7 C, 85 to 90% RH; CA 3 to 5% O2 and 5 to 10% CO2 extends shelf life.

B

Banana carriage
13.3 C pulp temperature, 90% RH, ethylene-sensitive, 4 to 5 week transits common from Latin America and West Africa to Europe and East Asia.
Banana ripening room
Shore-side controlled chamber that ethylene-treats green bananas at destination, 14.5 to 18 C.
Bay plan reefer
Stowage diagram identifying reefer slots and plug positions on container vessel.
Beef chilled carriage
-1.5 C deep chill, vacuum-packed primal cuts, 60 to 120 day shelf life.
Beef frozen carriage
-18 C or colder, blast-frozen, long-term storage stable.
Black box recorder
Reefer event memory storing setpoint, supply, return, and alarm history.
Blackberry carriage
0 C, 90 to 95% RH, MA packaging with elevated CO2.
Bleed valve
Service port for refrigerant charging or recovery on reefer unit.
Blocked stowage
Reefer cargo loaded tight against bulkheads, restricting air circulation; cause of hot spots.
Blueberry carriage
0 C, 90 to 95% RH, MA packaging 5 to 10% CO2 inhibits Botrytis.
Boil-off
Vaporization of cryogenic refrigerant (LN2, dry ice) used in expendable refrigeration units.
Bulkhead, return-air
Perforated wall at door end channeling air back to evaporator.
Bunker reefer
Older term for a vessel-supplied refrigerated cargo hold.

C

CA (Controlled Atmosphere)
Active gas management of O2, CO2, and N2 in reefer to slow respiration; typical 1 to 5% O2, 1 to 10% CO2, balance N2.
Captain Peter
Maersk Line digital reefer monitoring service giving shippers real-time temperature, humidity, and CA data.
Carbon dioxide (R744)
Natural refrigerant, GWP 1, used in NaturaLINE and other low-GWP container reefer units, transcritical cycle.
Carbon dioxide scrubber
Lime or amine bed inside CA unit removing excess CO2 from cargo respiration.
Carrier Transicold
US-headquartered manufacturer of container reefer units, including PrimeLINE, PrimeLINE Plus, and NaturaLINE.
Cellular respiration
Living-cargo metabolism producing CO2, water, and heat; basis for CA setpoint selection.
CFM
Cubic feet per minute, US measure of evaporator and fresh-air airflow.
Cherry carriage
0 C, 90 to 95% RH, MA or CA prolongs firmness; SO2 not used (damages cherries).
Chilled cargo
Product carried above its freezing point, generally -2 to 12 C depending on commodity.
Citrus carriage
Oranges 4 C, lemons 12 C, grapefruit 13 C, all 85 to 90% RH.
Cleaning, reefer
Wash and disinfect after each cargo; required before food-grade reuse.
ClimaCare
Maersk Container Industry service brand for spare parts and OEM support of Star Cool units.
Climacteric fruit
Fruit ripening with autocatalytic ethylene burst and respiration peak, e.g., banana, avocado, mango, apple.
Clip-on genset
Diesel generator clamped to a container front for road or yard reefer power, typically 15 to 25 kVA, 460 V 3-phase.
CMA CGM REEFLEX
CMA CGM IoT reefer monitoring service for live data and exception alerts.
Cold chain
Continuous temperature-controlled supply chain from origin packing house to retail or end-use.
Cold treatment, in-transit
APHIS-approved temperature regime applied during the reefer voyage to disinfest fruit-fly host commodities.
Cold-treatment compliant logger
USDA-approved temperature recorder meeting APHIS placement and accuracy specifications for in-transit cold treatment.
Compressor, scroll
Most common compressor type in modern container reefer units; orbiting and fixed scroll volumes.
Conair
Legacy porthole-system reefer container relying on external clip-on or vessel-supplied refrigeration via two ports; largely retired.
Condenser fan
Axial fan moving ambient air across condenser coil.
Controlled atmosphere generator
Onboard N2 separator and CO2 scrubber maintaining set gas mix during voyage.
Controlled room temperature (CRT)
USP definition 20 to 25 C with excursions 15 to 30 C, used for many pharmaceuticals.
Cool-down
Pre-trip lowering of empty container interior to set point before stuffing cargo.
CSC Plate
Container Safety Convention safety approval plate; verified on container surveys.

D

Daikin LXE
Daikin Industries container reefer unit family, including LXE10E.
Daikin Reefer Master
Daikin OEM telematics package for container reefer fleet monitoring.
Daikin Star Cooler
Marketing name used in some markets for high-efficiency Daikin reefer model.
Dairy carriage
0 to 4 C for fresh milk, cream, yogurt; HACCP and EU 853/2004 hygiene compliance required.
Damper, fresh-air
Mechanical or motorized vent adjusting outside-air introduction.
Data logger
Standalone or embedded device recording temperature, humidity, and sometimes gas composition.
Deck stow reefer
On-deck reefer slot, often with better ambient air but more solar gain.
Deep-freeze container
Reefer rated to approximately -29 to -35 C minimum, suitable for ice cream and frozen seafood.
Defrost cycle
Periodic evaporator heating to clear frost; initiated by timer, demand sensor, or pressure differential.
Dehumidification
Removing moisture from cargo hold air using refrigerant or desiccant units.
Delta-T
Temperature difference between supply and return air; indicator of cargo heat load and airflow.
Dew Point
Temperature at which water vapor condenses; key to ventilation decisions.
Discharge pressure
High-side refrigerant pressure at compressor outlet.
Drain hole
T-floor opening allowing defrost water and condensate to exit container.
Drainage, condensate
Continuous removal of evaporator drip pan water through floor drains.
Dry-ice CO2 charge
Expendable refrigeration system using solid CO2 sublimation; rare in international reefer trade.
Dwell time
duration containers or cargo remain in the terminal.

E

EBI (Emerson Brand)
Cargo-monitoring instruments historically branded EBI, now part of Emerson Cargo Solutions.
Economizer
Refrigeration circuit enhancement boosting capacity at low evaporating temperatures; standard on PrimeLINE and Star Cool.
Electronic expansion valve (EEV)
Stepper-motor refrigerant metering device; replaces thermostatic TXV in modern reefers.
Emerson GO Real-Time
Emerson satellite/cellular reefer telematics tracker.
Equipment Interchange Receipt (EIR)
Gate document recording reefer set point, machinery condition, and PTI status at handover.
Ethylene (C2H4)
Plant ripening hormone; produced by climacteric fruit, harmful to ethylene-sensitive cargo at parts-per-million levels.
Ethylene Scrubber
Filter in reefer to remove ripening hormone for sensitive produce.
EU F-Gas Regulation 2024/573
Recast HFC phase-down framework replacing 517/2014, restricts high-GWP refrigerants in new equipment.
EU Regulation (EC) 1/2005
Council Regulation on protection of animals during transport, including live animals in containers.
EU Regulation (EC) 178/2002
General Food Law establishing food safety principles in the EU.
EU Regulation (EC) 853/2004
Specific hygiene rules for food of animal origin.
Evaporator
Fresh water generator using waste heat from jacket water at low vacuum.
Evaporator fan
Centrifugal or axial fan circulating air through coil and across cargo.
Excursion
Maximum motion amplitude of cargo permitted before lashing failure.

F

Fan curve
Performance map relating fan static pressure and airflow.
FDA FSMA
US Food and Drug Administration Food Safety Modernization Act of 2011.
FEU per plug
Forty-foot equivalent reefer capacity per shipboard or terminal reefer outlet.
Floor, T-bar aluminium
Extruded aluminum reefer floor with longitudinal T-section channels guiding supply air under cargo.
Forced-air pre-cooling
Tunnel cooling of palletized produce before stuffing into reefer.
Frequency drive (VFD)
Variable-speed control for compressors and fans, key efficiency feature of PrimeLINE and Star Cool.
Fresh-air vent
Adjustable inlet allowing CO2 venting from respiring cargo; rated 0 to 280 m3/hr typically.
Frost protection
Setpoint management preventing chill injury on freeze-sensitive produce.
Frozen cargo
Product carried at -12 C or colder; common setpoints -18 C, -25 C, -29 C.

G

Genset, clip-on
Detachable diesel generator powering reefer during road or yard moves.
Genset, underslung
Chassis-mounted diesel generator for over-the-road reefer transport.
Globe Tracker
Vendor of satellite reefer telematics and CA monitoring devices.
Grape carriage
0 C, 90 to 95% RH, sulfur dioxide (SO2) generator pads control Botrytis.
Grapefruit carriage
Typically 13 C, 85 to 90% RH; chilling injury below 10 C.
Greenhouse warming potential (GWP)
100-year IPCC metric comparing refrigerant global warming impact to CO2.
Ground (earth) check
Pre-trip electrical safety test on reefer chassis bonding.

H

HACCP
Hazard Analysis and Critical Control Points food safety management system, codified in Codex Alimentarius.
Hapag-Lloyd LIVE Trace
Hapag-Lloyd online reefer tracking and exception monitoring platform.
Heat exchanger, plate
Compact brazed-plate evaporator option on some modern reefer units.
Heat load
Sum of conduction, infiltration, respiration, and lighting heat the reefer must remove.
HFC-134a (R134a)
Hydrofluorocarbon refrigerant, GWP 1430, being phased down in new container reefers under EU F-Gas.
HFC-404A (R404A)
HFC blend, GWP 3922, historically used in low-temperature container reefers.
HFC-407F (R407F)
HFC blend, GWP 1825, lower-GWP retrofit for R404A.
HFC-449A (R449A)
HFC/HFO blend, GWP 1397, R404A replacement.
HFC-452A (R452A)
HFC/HFO blend, GWP 2140, R404A replacement.
HFO-513A (R513A)
HFO/HFC blend, GWP 631, R134a replacement.
High-pressure cut-out
Safety pressure switch shutting down compressor on overpressure.
Hot stowage
Reefer placed near vessel heat source (engine room bulkhead, funnel uptake); to be avoided.
Humidity setpoint
Target relative humidity, typical 85 to 95% for fresh produce, 70 to 85% for some commodities.
Hybrid container vessel
Ship designed for both container and traditional refrigerated bulk operations.

I

ICCC
Inter-Carrier Container Code, used by carriers for plug-out reefer monitoring.
Identec Solutions
Provider of RFID and RTLS reefer monitoring hardware.
IDS (Independent Data Service)
Third-party temperature and event monitoring distinct from carrier or shipper systems.
In-transit cold treatment (ICT)
APHIS-approved on-board cold treatment under USDA SET protocol.
Insulation, polyurethane foam
50 to 100 mm CFC-free foam between inner aluminum and outer steel reefer skins.
Integral reefer
Container with built-in refrigeration unit and standardized power connection, dominant modern design.
IPPC ISPM 15
International Plant Protection Convention standard for treatment of wood packaging material; relevant to crates and pallets in reefer cargo.
ISO 1161
Corner fittings standard for series 1 containers.
ISO 14001
Environmental management standard often integrated with ISM.
ISO 1496-2
Specification for thermal containers, defines structural and insulation requirements.
ISO 22000
Food safety management system standard, applicable across the cold chain.
ISO 6346
ISO standard for container coding and marking.
ISO 668
ISO standard for container classifications and dimensions.
ISO 830
Container terminology standard.
ISO 9001
Quality management standard often integrated with ISM.

J

Job log
Reefer movement and PTI log retained at depot for QA traceability.
Juice concentrate carriage
Frozen or chilled fruit-juice concentrate, typically -18 C frozen or 4 C chilled.

K

Kiwi carriage
-0.5 to 0 C, 90 to 95% RH, ethylene-sensitive (high CO2 tolerance).
kVA, reefer plug
Apparent power capacity of vessel or terminal reefer socket, typically 15 to 18 kVA per plug.

L

Latent heat
Heat absorbed or released during phase change, dominant for ice/water and freeze-cycle cargoes.
Lemon carriage
12 C, 85 to 90% RH; chilling injury below 10 C.
Liquefied nitrogen (LN2)
Cryogenic expendable refrigerant for specialty reefer systems.
Liquid-line filter drier
Refrigerant moisture and contaminant filter on high-pressure liquid line.
Live animal container
Containers permanently fitted for livestock under EU 1/2005 and IMO MSC.1/Circ.1349.
Logger placement
Sensor position inside cargo or air stream specified by USDA cold-treatment and pharma protocols.
Low-pressure cut-out
Safety switch protecting compressor against loss of refrigerant charge.

M

MA (Modified Atmosphere)
Passive gas environment created by produce respiration inside sealed liner; no active gas injection.
Maersk Container Industry (MCI)
Manufacturer of Star Cool reefer units, sold to Chinese consortium in 2021; brand retained.
MAGNUM PLUS / Magnum 2.0
Thermo King deep-freeze and pharma-capable container reefer units.
Mango carriage
12 to 13 C, 85 to 90% RH; chilling injury below 10 C; ethylene-sensitive.
MARPOL Annex IV
Prevention of pollution by sewage.
Mass airflow
Cargo-traversing air mass per unit time; specified in some reefer commodity guides.
Modified Atmosphere Packaging (MAP)
Gas-flushed retail packaging carried in standard reefers.
Mother vessel reefer plug
Shipboard reefer socket, IEC 60309 type, 440 V 3-phase 60 Hz 32 A standard.
MSC MyMSC
Mediterranean Shipping Company digital reefer monitoring portal.

N

NaturaLINE
Carrier Transicold reefer unit using R744 (CO2) natural refrigerant.
Nitrogen flush
Pre-loading inerting of CA reefer atmosphere with bottled or generated N2.
No-frost coil
Evaporator design or control logic minimizing frost build-up.
Non-climacteric fruit
Fruit not exhibiting ripening respiration burst, e.g., citrus, grapes, strawberries.

O

O2 setpoint
Target oxygen concentration in CA reefer, typically 1 to 5% by volume for apple and avocado.
Operating compressor hours
Cumulative compressor runtime recorded by reefer controller.
Orange carriage
4 C, 85 to 90% RH; cold-treatment-host for fruit flies in many trade lanes.

P

Partial PTI
Reduced PTI subset performed on time-pressed turnarounds.
Pear carriage
1 C (Bartlett) to -1 C (some cultivars), 90 to 95% RH; CA extends storage.
PerishableCare
Maersk premium reefer service tier with stricter handling and monitoring.
Pharma reefer
Container with tighter temperature stability (typical 2 to 8 C) and validated mapping for pharmaceutical shipments.
Phytosanitary certificate
Plant health certificate.
Pineapple carriage
8 C, 85 to 90% RH; chilling injury below 7 C.
Plenum
Air distribution space above cargo and below ceiling, fed by supply duct.
Plug-in time
Period reefer is connected and powered at terminal, depot, or vessel.
Plug-out
Reefer disconnected, often during gate moves or hinterland transport.
Polyurethane (PUR) foam
CFC- and HCFC-free insulation, typical 50 to 100 mm thickness in reefer panels.
Porthole container
Insulated container without internal machinery; cooled by clip-on or vessel hold plant via two port openings; legacy.
Pre-Cooling
General term covering tank cool-down with LNG spray nozzles before bulk transfer.
Pre-trip alarm log
PTI record of triggered alarms during functional test sequence.
PrimeLINE
Carrier Transicold high-efficiency container reefer unit, R134a in current configurations.
PrimeLINE Plus
Updated PrimeLINE variant with enhanced energy performance and connectivity.
PTI (Pre-Trip Inspection)
Standardized depot-side functional test of reefer unit prior to release.
Pull-down time
Duration from start-up to reaching set point with cargo or empty.
Pulp temperature
Temperature measured inside fruit or muscle, critical compliance metric for cold treatment.

Q

QC sample
Cargo subset removed at gate or load for quality inspection.
Quick-freeze
Rapid freezing process; not normally performed inside reefer but described for cargo arrival condition.

R

R134a
HFC refrigerant common in AC plants, phased down under MARPOL Annex VI Regulation 12.
R290 (propane)
Hydrocarbon natural refrigerant, GWP 3, ASHRAE A3 flammable; limited container use.
R404A, R407F, R449A, R452A, R513A
See HFC entries.
R600a (isobutane)
Hydrocarbon refrigerant, GWP under 5, used in some small refrigeration appliances; not in container reefers.
R717
Ammonia refrigerant used on reefer carriers and some chillers.
R744
Carbon dioxide refrigerant used in modern reefer container and cruise installations.
Reefer Plug
Onboard or terminal 440 V socket for reefer power.
Reefer rack
Stack with power supply for reefer containers.
REEFLEX
CMA CGM reefer telematics platform.
Refrigerant charge
Mass of refrigerant in reefer circuit, typical 3 to 6 kg depending on unit.
Refrigerant leak test
Pre-trip electronic or dye-based leak survey.
Relative humidity (RH)
Ratio of water vapor in air to saturation at the same temperature.
Respiration rate
Volume of O2 consumed and CO2 produced per kg cargo per hour, temperature dependent.
Return air
Air drawn back to evaporator after passing across cargo; setpoint reference for chilled cargo.
Reverse logistics, reefer
Movement of empty reefer back to load port, often requiring depot inspection and PTI.

S

Salmon carriage
See Atlantic salmon.
Sanitary Transportation Rule
FDA FSMA rule (21 CFR Part 1, Subpart O) governing food transport.
Sashimi tuna carriage
-60 C super-freezer for sashimi-grade bluefin and yellowfin.
Scroll compressor
Dominant compressor architecture in modern reefer units.
Sensitech TempTale 4
USDA cold-treatment-compliant temperature data logger family.
Set point
Operator-specified target temperature for return or supply air.
SET protocol
USDA Maritime Cold Treatment in-transit compliance specification.
Shelf life
Period cargo retains marketable quality at specified temperature.
Shore power
OPS or cold ironing infrastructure, IEC/IEEE 80005 series.
Sniffer test
Refrigerant leak inspection using electronic halogen detector.
SO2 generator pad
Sulfur dioxide-releasing sheet packed with grapes to control Botrytis cinerea.
Solar gain
Heat absorbed from sunlight by deck-stowed reefers; reflective paint reduces impact.
Star Cool Integrated
Maersk Container Industry integrated reefer unit with R134a, slim design.
Star Cool Integrated SAA
Star Cool variant with sensor-controlled airflow for energy savings.
Stratification
Vertical density layering of the water column resisting mixing.
Strawberry carriage
0 C, 90 to 95% RH; MA with elevated CO2 controls decay.
Sub-zero treatment
Storage below 0 C for certain frozen and ultra-low-temperature cargoes.
Super-freezer
Reefer rated to -60 C or colder, used for sashimi tuna and some biologicals.
Supply air
Air discharged into cargo zone after evaporator; setpoint reference for frozen cargo.
Surface temperature
Cargo skin temperature, distinct from pulp temperature.

T

T-bar floor
Aluminum extruded floor with T-section air channels; standard reefer construction.
Temperature mapping
Validation exercise placing many loggers in empty container to characterize uniformity (pharma requirement).
Temperature uniformity
Maximum deviation between supply and return or among cargo positions.
TempTale
See Sensitech.
Terminal reefer monitoring
Yard service connecting, plugging, inspecting, and logging reefer events.
Thermal break
Insulating gasket reducing conductive heat transfer at door and corner posts.
Thermo King
US-headquartered reefer unit manufacturer (Trane Technologies), MAGNUM and MAGNUM PLUS lines.
Thermo King Magnum 2.0
Updated Magnum reefer with energy and pharma performance enhancements.
Thermostatic expansion valve (TXV)
Mechanical refrigerant metering device, largely replaced by EEV.
Three-phase, 60 Hz
Standard reefer power, 380 to 460 V depending on terminal or vessel.
Tracking, real-time
Continuous satellite or cellular reefer telematics.
Trim air
Conditioned air introduced via fresh-air vent for gas management.
Tuna carriage
Sashimi-grade -60 C super-freezer; other tuna grades -18 to -25 C.

U

Ultra-low temperature (ULT) shipment
Cargo carried at -60 to -80 C, e.g., COVID-19 mRNA vaccines via specialized active containers and dry ice.
UN R134a, R404A etc.
ASHRAE refrigerant numbers; UN dangerous goods numbers differ (e.g., UN 3159 for R134a).
Underdeck stow
Reefer slot in vessel hold, generally lower ambient and shielded from solar gain.
UNECE Working Party on Perishable Foodstuffs
Maintains the ATP Agreement.
USDA APHIS PPQ Treatment Manual
Definitive guide for approved phytosanitary treatments including cold treatment regimes.
USDA cold treatment schedules
14 days at 0 C, 16 days at 0.55 C, 18 days at 1.11 C, 20 days at 1.39 C, 22 days at 1.67 C for Mediterranean, oriental, and Caribbean fruit flies (T107-a).
USDA SET
Sea-borne in-transit cold treatment program.

V

Vaccine cold chain
2 to 8 C standard; -20 C frozen; -70 C ultra-cold for Pfizer-BioNTech COVID-19 vaccine.
Vacuum-pack beef
Primal cuts in oxygen-barrier film; 60 to 120 day chilled shelf life.
Variable Frequency Drive (VFD)
Speed control for cargo and send-out pumps reducing electrical consumption.
Ventilation setting
Fresh-air vent opening expressed in m3/hr or CFM.
Voltage, reefer
Common values 380 V (50 Hz), 440 V (60 Hz), 460 V (60 Hz).
VPD (Vapor Pressure Deficit)
Difference between saturation and actual vapor pressure; controls cargo moisture loss.

W

Water-cooled condenser
Vessel-side water loop condenser option for hold-stowed reefers; rare today.
Wattage draw
Real-power consumption of reefer unit, typical 2 to 8 kW at steady state.
WCO Harmonized System
Customs classification, reefer-relevant chapters include 02 (meat), 03 (fish), 04 (dairy), 07 (vegetables), 08 (fruit), 30 (pharma).
WHO Good Distribution Practices (GDP)
Pharma transport quality requirements applied to reefer movements.

X

X-Ray Inspection
Radiographic NDT method for weld root and internal defects.
XtendFresh
Carrier Transicold controlled-atmosphere kit retrofitted to integral reefers.

Y

Yard plug
Depot reefer power outlet, often 32 A, 440 V 3-phase 60 Hz.